Operation Manual
Table Of Contents
Back Panel Interface
71
PLM Series Operation Manual Rev 1.3.0
Tests indicate that up to 20 PLMs may be have
their AES3 inputs daisy-chained together, however
circumstances and cabling used may reduce this
gure. Please refer to section 10.6.
8.4 RJ45 etherCON Network Connections
Two RJ45 etherCON style network connections are provided as shown in Figure 8-16.
Figure 8-16: etherCON Network Connectors
The switched 100/100 Base-T network connections auto-sense whether standard or crossover Cat-5e
cables are in use. The green ACT LED illuminates (ashes) to show network activity, and when a 100 Mbps
connection is present; the orange LED illuminates (static) to indicate a 1000 Mbps connection.
Pre-made cables with moulded RJ45 plugs are recommended. If it is necessary to make up custom Cat-5e
network cables, use pinout described in Table 8-4.
Pin No. Color
1 Brown
2 Brown + White
3 Green
4 Blue + White
5 Blue
6 Green + White
7 Orange
8 Orange + White
Table 8-4: RJ45 Wiring & Pin Out Description