QuickStart Start and FieldReference Reference Guide Quick & Field Guide Operation Manual PLM™ Series Powered Loudspeaker Management™ systems Rev 1.3.
Important Safety Instructions 1. Important Safety Instructions Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times. 1.1 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings.
Important Safety Instructions 1.4 WARNING To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture. Pour réduire les risques de blessure ou le choc électrique, n’exposez pas l’appareil à la pluie ou à l’humidité. Do not expose this system/apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the apparatus.
Important Safety Instructions ▸▸ Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. ▸▸ Check if the affected unit complies with the EMC limits for immunity, (CE-labeled). If not, address the problem with the manufacturer or supplier. All electrical products sold in the EC must be approved for immunity against electromagnetic fields, high voltage flashes, and radio interference. ▸▸ Consult the dealer or an experienced radio/TV technician for help.
Table of Contents 1. Important Safety Instructions ����������������������������������������������������������������������������������������������������������������i 1.1 Important Safety Instructions ��������������������������������������������������������������������������������������������������������������� i 1.2 Standards ���������������������������������������������������������������������������������������������������������������������������������������������� i 1.
8.1 8.2 8.3 8.
Welcome 2. Welcome 2.1 Introduction Thank you for choosing the Lab.gruppen PLM Series of Powered Loudspeaker Management systems for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long-term durability offered by this product.
Welcome 2.2.2 Amplifier DSP (Digital Signal Processor) Various features of PLM Series devices are controlled by the on-board DSP, some of which are summarized in this section. 2.2.2.1 Input Gain (Sensitivity) Input gain (sensitivity) is set in the digital domain for PLM Series devices, and may be controlled via the Lake Controller software or front-panel interface. 2.2.2.2 ISVPL™ The Inter-Sample Voltage Peak Limiter (ISVPL) tailors each power output to the characteristics of the connected load.
Welcome Please refer to the Lake Controller Operation Manual for further information regarding the Analyzer plug-in and associated functionality. 2.2.5 Dante™ Audio Network PLM Series devices include Dante digital audio networking as standard. Utilizing the latest advances in Ethernet technology, Dante offers simplified system configuration and extremely low latency while delivering very high quality uncompressed digital audio across the Lake network.
Installation 3. Installation 3.1 Unpacking Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every Lab.gruppen product is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a claim with the carrier or their insurers for damage incurred during shipping.
Installation Figure 3-1: Rear Support Bracket and Mounting Hardware Figure 3-2: Use the Washer for Fixed Installations Figure 3-3: Use Tube for Slide-On Installation PLM Series Quick Start and Field Reference Guide Rev 1.3.
Installation 3.3 3.3.1 Cooling Overview The PLM Series devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. Front-to-rear airflow is preferable as air at the front of a rack is cooler than that at the rear in nearly all situations; never attempt to reverse the airflow.
Installation The PLM uses primary switching, which means the mains power is rectified on the primary side of the transformer. This makes the power supply insensitive to mains frequency variation, and it will operate normally on line frequencies from 45 to 75 Hz.
Product Overview 4. Product Overview This chapter provides an overview of key features and functionality. For further information please see chapters 5 to 9 of the PLM Series Operation Manual. 4.1 Front Panel Overview Figure 4-1: Front Panel Overview The front panel controls are clustered around a daylight readable LCD , allowing adjustment and monitoring of the majority parameters and meters.
Product Overview Display The display illuminates when the device is on. The LCD, function buttons, and the rotary encoder provide real-time control and monitoring of most parameters. The LEDs embedded in the function buttons indicate available menu options, provide confirmation of Controller communication, and indicate various faults and warnings. The brightness and contrast of the display and front panel LEDs can be adjusted via the front panel menu.
Product Overview The LED in the top button provides Frame fault and warning indications. The middle two buttons provide Module input mute functionality, mute indication and faults and warning indications relating to the PLM inputs. The bottom button is used only in Menu Mode or to lock the front panel buttons. Please refer to chapter 6 of the PLM Series Operation Manual for further details.
Product Overview 4.2 Back Panel Overview Figure 4-2: Back Panel Layout Options for a 4-channel PLM Figure 4-3: Back Panel Layout Options for a 2-channel PLM PLM Series Quick Start and Field Reference Guide Rev 1.3.
Product Overview 4.2.1 Input and Link Connectors Analog Inputs Analog inputs are available on two standard XLR3F latching connectors. The inputs are electronically balanced and feature Lake Iso-Float circuitry. The impedance is 20 kohms, and the inputs can accept a maximum input level of +26 dBu. Analog Links Two latching XLR3M connectors are fitted adjacent to the analog input connectors.
Product Overview Binding Posts In this version, the power outputs for loudspeaker connection are available on four separate pairs of fully enclosed binding posts. Bridge Mode can be enabled via the Lake Controller software, please refer to the Lake Controller Operation Manual for further information. Channel configuration for the binding posts is dependent on the PLM model, please refer to section of the PLM Operation Manual for standard and Bridge Mode wiring.
Product Overview The Ethernet ports operate at the Ethernet data rate of 100 Mbps, and allow straight or crossed network cables. Two LEDs above each port indicate valid network connection (LINK) and network activity (ACT). Secondary Connector The secondary network connector can be used to daisy-chain multiple LM & PLM Series devices.
Signal Flow and Lake Processing 5. Signal Flow and Lake Processing 5.1 Signal Flow The figures below depict the audio signal flow for a PLM Series device. It is worth noting that this sophisticated device provides seven points in the signal chain where the signal level can be adjusted, muted or disconnected. The blue sections represent Frame data, and the red sections represent Module data - please refer to the Lake Controller Operation Manual for further information.
Signal Flow and Lake Processing Output Router Stage - Output on/off routing connections Attenuation Stage - Power output channel mute and attenuation settings Amp Gain Stage - Amplifier gain control If the required audio signal is not passing correctly, verify the connection, mute and gain settings at all seven stages. 5.1.
Signal Flow and Lake Processing The sophisticated output section monitors faults and generates warnings when appropriate; warnings are displayed on the front panel of the PLM and also sent as messages over the control network. In the rare event that maximum ratings are significantly exceeded, the PLM will mute until the condition has been rectified or the incorrect setting has been readjusted.
Signal Flow and Lake Processing 5.3 5.3.1 Modules and Frames Overview A Frame represents one physical Lake Processor (e.g. PLM 10000Q). A maximum of two Modules are contained within each Frame; these are referred to as Module A and Module B. The number of Modules shown in a given Frame is dependent upon the signal processing configuration of that Frame.
Signal Flow and Lake Processing 5.4 Loudspeaker Processor Overview The Lake Processing system within PLM Series devices may be configured with up to two processing Modules containing a total of up to six processing Module outputs, although the number of power outputs will be either two or four depending on the PLM model being used. To make use of the extra processing channels, multiple hardware devices may be connected together using the Super Module feature as summarized in section 5.3.3.
Signal Flow and Lake Processing A maximum of 100 Frame Presets can be stored on this device. The data within a Frame Preset includes the configurations of all Modules in the Frame, including levels, crossover, EQ, input mixer, routing, and all other parameters. As Frame Presets are stored in the hardware device, recall is available without using a PC.
Quick Start Tutorial 6. Quick Start Tutorial 6.1 Introduction This section describes installation of the Lake Controller software, input and output connections, basic functionality, and setup instructions. The information provides a basic level of understanding of the system architecture along with configuration instructions for a basic system application. The tutorial in section 6.4 provides a step-by-step example for configuring this device for use with a generic professional sound system.
Quick Start Tutorial ▸▸ 100/1000 Base-T wired Ethernet adapter and/or 802.11 wireless Ethernet adapter ▸▸ A touch-screen Tablet style interface is recommended for optimal user experience The minimum computer specifications for using the Lake Controller software are: ▸▸ 1 GHz Processor ▸▸ 512 MB RAM ▸▸ 128 MB video RAM WinXP, “emulation” for Win 7 (ensure latest video drivers are installed) ▸▸ Windows XP Service Pack 2 ▸▸ Microsoft DirectX® 8.
Quick Start Tutorial 6.3.5 Ethernet Configuration This device provides control, monitoring and digital audio functionality via an Ethernet network. For further information on the setup and configuration of an Ethernet network, please refer to the Lake Controller Operation Manual and the Lake Network Configuration Guide. 6.
Quick Start Tutorial 5. After ensuring that no audio is being output from the mixing console, power on the PLM. 6. On the Tablet PC, launch the Lake Controller software application. Select the appropriate network adapter if more than one is enabled, and tap NO to the dialog asking whether to load the previous configuration. 7. Tap MODULES to access the Module Menu and scroll bar. 8. On the Module scroll bar, the PLM is represented with a frame containing two discs.
Quick Start Tutorial 21. Tap the POST EQ button so it changes to read INPUT MIX. 22. Tap any of the blue INPUT MIXER summary blocks associated with the Auxiliary Output channel to open the separate Aux Input Mixer. 23. Ensure INPUT 2 is turned on and set to 0.00 dB, and that all other inputs are OFF. 24. Tap the bottom-right return button to close the Aux Input Mixer. 25. As Module B’s processing is not required for this configuration, open Module B’s input mixer, and turn all inputs OFF.
Quick Start Tutorial ▸▸ INPUT CONFIGURATION: #1: Auto Type: Analog #2: Auto Type: Analog ▸▸ DANTE CONFIGURATION: Dante Disabled ▸▸ Analog Iso-Float & AES Termination: Inputs 1-2: Floating AES: Terminated Offset/Headroom: 26 dBu Offset/Headroom: 26 dBu 31. Tap EVENTS & CONTROL to access various amplifier specific information and options, including four amplifier attenuation controls on the STATUS tab. As a precaution, drag all four faders to the minimum position. 32.
Quick Start Tutorial 40. From I/O CONFIG, tap EVENTS & CONTROL and navigate to the STATUS tab. Slowly increase the attenuation faders to turn up the amplifier channels. If the PLM is connected to loudspeaker, audio should now be heard. 41. Use the powerful XOVER, AUX, PEQ and GEQ screens to tune your loudspeaker as required. Please refer to the Lake Controller Operation Manual for detailed information on these features. 6.
Quick Start Tutorial 6.5.5 Attenuator An attenuator gain adjustment is provided for each power output channel in the PLM (-inf to 0 dB. This control replaces the traditional volume control found on conventional amplifiers and should typically be left at 0 dB during use. 6.5.6 Amp Gain The Amp Gain corresponds to the gain adjustment in a conventional separate loudspeaker processor and amplifier system.
Technical Specifications 7. Technical Specifications Model Number of input channels Number of output channels Peak total output all channels driven Max. Peak output voltage per channel Max. output current per channel PLM 20000Q 2 4 20000 W 194 V 67 A peak PLM 14000 2 2 14000 W 193 V 90 A peak PLM 10000Q 2 4 10800 W 153 V 49 A peak Max. Output Power 16 ohms per ch. (all ch.’s driven) 8 ohms per ch. (all ch.’s driven) 4 ohms per ch. (all ch.’s driven) 1) 2 ohms per ch. (all ch.
Warranty and Support 8. Warranty and Support 8.1 General This product is manufactured by Lab.gruppen, and it is warranted to be free from any defects caused by components or factory workmanship, under normal use and service, for a period of six (6) years from date warranty period, Lab.gruppen will undertake to repair, or at its option, replace this product at no charge to its owner, provided the unit is returned undamaged, shipping prepaid, to an authorized service facility or to the factory.
Warranty and Support 8.3.2 Factory Service In the event a Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service department for return instructions and a Return Authorization number. Please note for product return: 1. Use the original packing. 2. Include a copy of the sales receipt, your name, return address, phone and fax number, email address and description of the defect. 3. Mark the Return Authorization number on the outside of the packing. 4.
Quick Start and Field Reference Guide Operation Manual LAB.GRUPPEN AB ► SWEDEN INTERNATIONAL CONTACT ► INFO@L ABGRUPPEN.COM WWW.LABGRUPPEN.