Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.8
Lake-enabled Amplifier Reference
273
20.13.6 Global Dante Enabled Control
Two buttons, ON and OFF, control the Dante Enabled status of all devices that are online and present in the
current system conguration (not applicable for MY8-LAKE). A conrmation is required prior to changing this
status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status. Status indicators summarize the number of online devices in the current system
conguration that have this status set to ON or OFF.
Two additional buttons, 48 kHz and 96 kHz control the Dante sample rate for all Dante-enabled devices in
the current system conguration.
20.13.7 Global Dante Transmit Enabled Control
Two buttons, ON and OFF, control the Dante Transmit Enabled status of all devices that are online and
present in the current system conguration (not applicable for MY8-LAKE). A conrmation is required prior
to changing this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
20.13.8 Global AES67 Enable Control (PLM+ and D Series only)
Two buttons, ON and OFF, control the AES mode on all supported devices present in the system congura-
tion. Unsupported devices are listed in the n/a counter. All devices with AES67 mode enabled are listed
under ON, and all devices with AES67 mode disabled are listed under OFF. Since devices are required to
re-start when AES67 mode is changed, during the re-start devices will be listed under Pending.
20.13.9 Global Auto Power Down Control (PLM+ and D Series only)
Two buttons, ON and OFF and additional status information describe how Auto Power Down is congured
for the devices in the current system conguration.
If Auto Power Down is enabled (ON), the selected device will automatically go into standby mode after the
denes number of minutes has been reached where the following criteria is met:
▸ No audio is passing
▸ No user interaction via Lake Controller