Lake Controller Operation Manual

Table Of Contents
284
Lake Controller Operation Manual Rev 1.6.1
Global Events and Control
2. Tap GLOBAL INFO.
3. Tap EVENTS & CONTROL [F8]
4. Tap the CONTROL tab
Figure 23-3: Global Control Tab
23. 2 .1 Global Power Control
Two buttons, ON and STANDBY, control the power status of all Lake-enabled devices (except MY8-LAKE)
that are online and present in the current system conguration. A conrmation is required prior to changing
this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators to the right of the buttons show the total number of LM and PLM Series devices in the
current system conguration that are ON, in STANDBY or OFFLINE.
If the Global Power Control default sequence time
is too quick, causing issues for the power distribu-
tion, this can be changed from the iC.ini file located
in the Config folder of Documents. The setting is
GLOBAL_POWER_DELAY and it is specified in ms.