Lake Controller Operation Manual
292
Lake Controller Operation Manual Rev 1.5.4
Firmware Update
Figure 26-2: Network Adapter Selection
5. Select the wired adapter to which the Lake devices are connected.
The Lake devices will appear in a list with their current rmware versions displayed, similar to that shown in
Figure 26-3. The rmware version to be loaded is shown at the top of the screen (target rmware); this will
default to the latest version available.
Figure 26-3: Lake Update Utility Main Screen
For PLM+ and D Series, the rmware update utility must be able to read the Dante component before the
rmware update can start; ensure the network adapter selected for rmware update is on the same subnet
as Dante (169.254.x.x) and ensure the Lake Update Utility has full access through the rewall.