9. Appendix
9.1 Faults and Warnings Overview
Fault or warning conditions are indicated by the LED shown in Figure 7-3 on page 34, and also by LEDs associ-
ated with the inputs and outputs on the PLM. As the LEDs indicate several types of faults or warnings, a
brief textual description of the fault or warning is provided on the LCD display. Section 7.8.2 on page 34 details
the fault and warning indications that appear on the front panel. Table 9-1 lists the events that may have
triggered each fault or warning condition.
Model Displayed Text Event Log Text Category Description
ALL AMP CH. MUTE Amp Channel Mute Mute The audio signal has been muted in the
power output stage.
ALL ANALOG IN
FAULT
Frame Fault: Analog Input Fault The analog input signal is corrupt due
to DC on the analog input, or there is an
issue with the internal A/D converter.
20000Q ATL ACTIVE N/A Warning The output power is limited due to high
amplier channel temperature - the amp
channel temperature limiter is active.
ALL AUDIO FAULT Frame Fault: Audio Interface Fault An internal audio fault has arisen and the
unit needs servicing.
20000Q BEL ACTIVE N/A Warning Breaker Emulation Limiter present as the
nominal current reached. Improve the
power distribution and adjust the BEL
settings.
ALL CAL ACTIVE n/a Fault Ensures that the PLM’s power output
stages are not overloaded. This should
never happen during normal program
material.
20000Q CHECK AC
MAINS
Frame fault: Check AC Mains Fault The PSU received unstable mains, check
the mains conguration.
ALL CLOCK SLIPPING AES Clock slipping Warning The AES or Dante clock is slipping; verify
clock selection / generator. This will
cause high THD on signal, and if Dante
is running will result in an unstable signal
distribution.
ALL CTRL OFFLINE N/A Warning The PLM is no longer able to communi-
cate with the Lake Controller.
ALL CURRENT CLIP n/a Clip PLM’s power output stage current has
exceeded the xed safe maximum and
the Current Peak Limiter has become
active to limit it.
ALL INPUT CLIP n/a Clip The input signal level is too high and is
causing clipping at the input stage