User guide

36
Front Panel Interface
PLM Series Operation Manual rev 1.2.3
7.8.4.1 Mute Functions
The PLM provides mute functions at several different points in its audio chain. Please refer to section 6.1 for
further information. The four types of mute are:
1. PLM Input Mute
2. Module Input Mute
3. Module Output Mute
4. Power Output Mute
With the exception of Module output mutes, all types may be controlled from the PLM front panel in Meter
Mode by activating MUTE ENABLE and selecting the associated input or output Meter View using the
METER button.
Module input and output mutes can be controlled in
Menu Mode via the MENU button. All mutes can
also be controlled from the Lake Controller.
7.8.4.2 PLM Input Mute
The PLM input mute provides the ability to simultaneously mute/unmute all modules or outputs that are
sourced from the PLM input. To mute or unmute the PLM inputs:
1. Press METER until the Input Meter View is displayed
2. Press MUTE ENABLE
3. Use the associated dynamic function buttons to mute / unmute the PLM inputs
The PLM Input Mute is within the Lake Processing
system, post input type selection, and pre input
mixing and routing.
Please refer to the Lake Controller User Manual for details of mute selection via the software.