User guide

Front Panel Interface
45
PLM Series Operation Manual rev 1.2.3
Unused in Temperature View
Output 1: AMP - Temp of power output VC - Temp of voicecoil MAG - Temp of magnet
Output 2: AMP - Temp of power output VC - Temp of voicecoil MAG - Temp of magnet
Output 3: AMP - Temp of power output VC - Temp of voicecoil MAG - Temp of magnet
Output 4: AMP - Temp of power output VC - Temp of voicecoil MAG - Temp of magnet
AMP indicates the current actual temperature of that channel’s power output stage as a percentage of
its maximum permitted value. The numerical value is in dB relative to signal clip.
The computed temperature of voice coil (VC) of the loudspeaker connected to that output channel. This
parameter is calculated using the power currently being dissipated in the load, and by using the loud-
speaker data from the LoadLibrary Fingerprint as presented by the SpeakerSafe output. The numerical
value is displayed in degrees Celsius.
The computed temperature of the magnet (MAG) of the loudspeaker connected to the output channel.
This parameter is calculated and displayed in a similar way to the voice coil (VC) temperature.
7.10.4 Input View
Input View enables inspection of the input signal before the input mixer (i.e. prior to the Home View Module
input meters).
Figure 7-8: Meter Mode > Input View
Current View title & Frame label, Frame faults and warnings
Input Router 1: Selected input type, input gain level (relative to clip), router fault/warning/clip
Input Router 2: Selected input type, input gain level (relative to clip), router fault/warning/clip
This section displays conrmation of the following settings: