User guide

74
Appendix
PLM Series Operation Manual rev 1.2.3
Model Displayed Text Event Log Text Category Description
ALL INPUT MUTE Input Mute Mute The audio signal has been muted at the
input router of the Lake Processor.
ALL LM PREC. LOW Speakersafe precision low Warning A SpeakerSafe warning indicating insuf-
cient data to produce reliable results.
This may occur, for example, if a channel
is being driven at a very low level.
ALL LOAD NOT VER LoadSmart: Load Not Veried Warning A Module containing a Fingerprint has
been loaded, but the load is yet to be
veried with LoadSmart.
20000Q MAINS <65 V Frame fault: PSU mains <65 V Fault Mains input voltage is below 65 Volts
RMS.
20000Q MAINS >270 V Frame fault: PSU mains >270 V Fault Mains input voltage is above 270 Volts
RMS.
20000Q MAINS >400 VPK Frame fault: PSU mains >400
VPK
Fault Mains input voltage is above 400 Volts
Peak.
20000Q MAINS GLITCH Glitch on mains voltage
detected
Warning A glitch (missing cycles) on mains input
was detected.
ALL MOD. IN MUTE Module Input Mute Mute The audio signal has been muted at the
Module input of the Lake processor.
ALL MOD. OUT MUTE Module Output Mute Mute The audio signal has been muted in the
output stage of the Lake processor.
ALL MODULE CLIP n/a Clip The signal level on the outputs of the
Lake processing module is too high and
is clipping.
ALL n/a LoadSmart Verication Event LoadSmart load verication is in
progress.
ALL n/a Sound Source Changed Event The input router has changed sound
source.
20000Q NEED SERVICE:1 Frame fault: Need Service: 1 Fault Service required, contact your dealer.
20000Q NEED SERVICE:2 Frame fault: Need Service: 2 Fault Service required, contact your dealer.
20000Q NEED SERVICE:3 Frame fault: Need Service: 3 Fault Service required, contact your dealer.
20000Q NEED SERVICE:4 Frame fault: Need Service: 4 Fault Service required, contact your dealer.
20000Q NEED SERVICE:5 Frame fault: Need Service: 5 Fault Service required, contact your dealer.
20000Q NEED SERVICE:6 Frame fault: Need Service: 6 Fault Service required, contact your dealer.
20000Q NEED SERVICE:7 Frame fault: Need Service: 7 Fault Service required, contact your dealer.
20000Q NEED SERVICE:8 Frame fault: Need Service: 8 Fault Service required, contact your dealer.
ALL NO INPUT No Input Source Fault The chosen input type has been
deselected or lost and the input type
selector has no alternative input sources
in the priority list.
ALL NO LOAD Channel Fault: No Load
Detected
Fault No load detected at the power output
channel.
ALL OFFLINE Frame Ofine Warning The Lake Controller cannot communicate
with this Lake device.