User guide

Appendix
81
PLM Series Operation Manual rev 1.2.3
PLM 10000Q
Level Load Rated power Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby 4.8 0 4.8 16 4
Powered on, idling. 145 0 145 496 125
Amp (I) Watt
Pink noise (1/8
rated power)
16 Ω / Ch. 660 x 4 9.3 4.8 687 330 357 1218 307
8 Ω / Ch. 1300 x 4 16.3 8.5 1250 650 600 2048 516
4 Ω / Ch. 2300 x 4 25.2 13.2 2014 1150 864 2949 743
2.67 Ω / Ch. 2700 x 4 31.3 16.4 2553 1350 1203 4106 1034
2 Ω / Ch. 2350 x 4 29.2 15.2 2341 1175 1166 3980 1003
Pink noise
(max power)
*3)
16 Ω / Ch. 660 x 4 14.7 7.7 1098 660 438 1495 377
8 Ω / Ch. 1300 x 4 26.0 13.6 2049 1300 749 2556 644
4 Ω / Ch. 2300 x 4 45.8 23.9 3746 2300 1446 4935 1243
2.67 Ω / Ch. 2700 x 4 52.5 27.4 4420 2700 1720 5870 1479
2 Ω / Ch. 2350 x 4 51,0 26.6 4179 2350 1829 6242 1573
20 kHz
Surveillance
tone
16 Ω / Ch. 1 x 4 2.7 1.4 160 4 156 532 134
16 Ω / Ch. 0.25 x 4 2.5 1.3 149 1 148
505 127
Mains connector - 230 V CE version / 230 V ETL version / 115 V ETL version 32 A, Neutrik
@
PowerCon
@
Twist lock
*1) The power output section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead,
measured and speci ed here is what is known as the “Active Power” of the power output section providing useful, real-world values of power
consumption and heat dissipation.
*2) Current draw  gures measured at 230 V. 115 V  gures are converted from 230 V  gures.
*3) Figures measured at maximum sustainable power without tripping the mains breaker. Listed separately for 30 A/115 V and 16 A/230 V operation.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped
even if operation is momentarily in excess of max. ratings.
Table 9-4: PLM 10000Q Current Draw & Thermal Dissipation