Manual

Lake Controller Operation Manual Rev 1.5.4
EQ/Levels Menu Reference
99
CROSSOVER SET is not applicable for the Linear
Phase Brick Wall 4-Way crossover.
6.4.7.4 Filter Bypass/Filter Insert
This button reads FILTER BYPASS when a parametric lter is selected, or when a crossover lter has been
split. For parametric EQ lters, select the lter box and tap FILTER INSERT / FILTER BYPASS to activate or
deactivate the selected lter.
A crossover HPF/LPF lter can be disabled by splitting the crossover and tapping FILTER BYPASS, followed
by OK on the warning conrmation dialog.
Linear phase crossovers, or combined Classic
crossovers, cannot be bypassed. To bypass the
Module’s overall HPF or LPF, toggle the HPF
ENABLE / LPF ENABLE button.
6.4.8 Filter Flat
The FILTER FLAT button is active only when a PEQ lter is selected. The function is inactive if a crossover is
selected. Tap FILTER FLAT to set the lter gain to zero and leave frequency/bandwidth unchanged.
6.4.9 Filter Delete
The FILTER DELETE button is active only when a PEQ lter is selected. The function is inactive if a cross-
over is selected. Tap FILTER DELETE to remove the selected PEQ lter from the overlay.
6.4.10 Filter Edit
Tap FILTER EDIT to manually enter values for a selected lter using the on-screen (or external) keyboard.
The values available for adjustment depend on whether a crossover or PEQ lter is selected. For a cross-
over, HPF or LPF only the frequency can be edited; for a parametric EQ lter the gain (dB), frequency (Hz),
and width (octave) can be edited.
To manually edit a lter:
1. Tap the lter box, then tap FILTER EDIT.
2. Tap the value to edit at the top of the screen (highlighted in blue).