102
Lake Controller Operation Manual Rev 1.5.4
EQ/Levels Menu Reference
4. Select an Auxiliary Output le from the scroll bar, and tap RECALL.
5. Read and tap YES to both warning messages.
Figure 6-18: Loading an Auxiliary Output le
6. After loading an Auxiliary Output Module le, access EQ/LEVELS for this Module by tapping
STORE/RECALL EXIT, then tap EQ/LEVELS
6.5.3 Adding Output-Specic EQ
The available overlays for the 3-Auxiliary Outputs Module are shown in Figure 6-19.
:
Figure 6-19: Auxiliary Output Tabs for 3-Aux Module
The Levels, PEQ & GEQ screens are the same for all Module types. Refer to section 6.1 for further informa-
tion.
The XOVER tab is not displayed as it is not relevant for this Module type. The XOVER tab will be present for
the Classic 2-Way + 1-Auxiliary Outputs (CL2w+1a) Module.
Three additional AUX tabs are present, providing individual high-pass, low-pass, and EQ lters for each
output.
1. Tap AUX -1 to select the Auxiliary Output tab for output 1.
2. Add a low and a high-shelf lter.
The screen should look similar to Figure 6-20.