Manual

148
Lake Controller Operation Manual Rev 1.5.4
Modules Menu Reference
8. 2 .13 Input Selection (MY8-LAKE in Simplied View Only)
The MY8-LAKE device has a unique simplied view for the Mesa Frame conguration by default. In this
view the input can be easily toggled between default Host output and AES input. Please refer to “8.2.7.2
Input Mixer” on page 137 and “22.4 I/O Conguration View Mode Options” on page 280 for further
information.
8. 2 .14 Frame Cong/Soft Reset
For Lake-enabled ampliers this button reads SOFT RESET and resets the device to its factory default state,
without removing any presets stored in the device, and without resetting the networking conguration data
including IP Cong, IP Address, Subnet Mask & Dual Redundancy settings.
For LM Series and MY8-LAKE devices, this button reads FRAME CONFIG and provides a sub-menu
allowing the device to be congured as:
CONTOUR (2-Contour Modules for LM Series; 4-Contour Modules for MY8-LAKE)
MESA EQ (4-Mesa EQ Modules for LM Series; 8-Mesa EQ Modules for MY8-LAKE)
CONTOUR/MESA EQ (2-Contour Modules and 4-Mesa EQ Modules - MY8-LAKE)
For all products, conguring or resetting a device via
the Lake Controller retains the current IP address
setting and system/Frame presets.
8.3 Label & Lock
From the Modules menu, tap LABEL & LOCK to view a submenu with functions to label a Module or Frame
and allow a system designer to lock Module and base congurations
8. 3.1 Module Label
The Module Label is a user-denable value at the bottom of the Module icon that identies the Module.
To label a Module:
1. Tap the desired Module icon on the MAIN page.
2. Tap MODULE LABEL, enter a Module name, and tap OK.