Manual
Lake Controller Operation Manual Rev 1.5.4
Modules Menu Reference
155
1. Navigate the le system, and tap the desired destination folder to select it.
2. Tap NEW STORE.
3. Enter the le name.
4. Tap OK.
The scroll bar displays the new le
8.6.4 Base Conguration
A base conguration le denes a starting point for the Module setup. It contains EQ and levels settings,
invisible to the user, which represent the appropriate general conguration for a particular speaker type.
EQ, LEVELS and XOVER settings for an existing Module may be stored as a base conguration for future
use when conguring new Modules. A system designer can also lock access to the XOVER/AUX screens
(Contour) or HPF/LPF screen (Mesa EQ) within the base conguration le. For details on this function,
please refer to chapter 19.
The RECALL/OPEN, STORE, and NEW STORE functions operate identically as described above, but the
available les/folders in the scroll bar change when BASE CONFIGURATION is selected.
To store or recall a base conguration le, perform the following steps:
1. Select a Module icon in the work area.
2. Tap MODULE STORE/RECALL from the MODULES menu.
3. Tap BASE CONFIGURATION.
4. Navigate to the desired folder/le.
5. Use the RECALL/STORE/NEW STORE functions as required.
A base conguration le cannot be created from a
Virtual Frame.
8.6.5 File Utilities
This button provides a submenu containing further functions that manage les and folders from within the
Lake Controller.