72
Lake Controller Operation Manual Rev 1.5.4
EQ/Levels Menu Reference
4. Tap LABEL CHANNEL to exit this mode.
6.2.7 Meter Options
Tap the METER OPTIONS button to view a submenu containing functions relating to alternate meter views
and system designer features.
6.2.7.1 Input +4dBu Reference
Tap INPUT +4dBu REFERENCE to view the physical input signal meter relative to +4 dBu.
Tap the button again to return to the default Digital Clip [DClip] view.
The DClip metering mode shows the audio level prior to any gain adjustment (input headroom, or digital gain
offset), and indicates when the A/D converters will clip. The +4 dBu metering mode shows the audio level
after any gain adjustment, and is useful for comparing levels of different input signals prior to processing.
This is a global function; all physical input meters throughout the system display the reference selected here.
6.2.7.2 Pre Limiter
Tap the PRE LIMITER button to view the pre-limiter output signals. Tap again to return to post-limiter mode.
This is a global function; all meters throughout the system display the reference selected here.
The limiter status is identied on the bottom right of
each output meter above the channel label/mute
button.
6. 2.7.3 AmpClip Reference
Tap the AMPCLIP REFERENCE button to view output signals with respect to the AmpClip reference level.
Tap again to return to the normal view, which is relative to the factory MaxRMS level as dened using
Designer Mode.
When AMPCLIP REFERENCE is selected, the Amp Clip level is used as the reference for the 0 dB level on
the meter. With correct settings, the output meter will identify the onset of clipping.
AMPCLIP REFERENCE is a global function; all meters throughout the system display the reference selected
here.