3.3. Cooling
3.3.1. Overview
The PLM+ Series devices use a forced-air cooling system with airow from front to rear, allowing high continuous
power levels without thermal problems. Front-to-rear airow is preferable as air at the front of a rack is cooler than
that at the rear in nearly all situations; never attempt to reverse the airow. The operation of the PLM+’s cooling
system is dependent on front-to-rear airow; it will not function effectively with external airow in the opposite
direction.
Make sure an adequate air supply is provided in front of the PLM+, and that the rear of the PLM+ has sufcient
space to allow air to escape. If the PLM+ is rack-mounted, never operate the unit with any front or rear rack doors
or covers in position. It is recommended to keep the ambient temperature around the PLM+ as cool as possible.
An increased temperature can have a signicant negative impact on the expected lifetime on the components
inside the PLM+.
Note: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation.
Leaving gaps in between items of equipment degrades the effectiveness of forced-air cooling.
If installing one or more PLM+ Series devices in a rack with other fan-cooled equipment, be sure that all the
other equipment also uses front-to-rear airow for cooling. If this precaution is not observed, there is a risk of
overheating, as units with the reverse airow will be drawing in air which has already been heated by the PLM+s.
3.3.2. Temperature Sensing and Protection
The PLM+ is equipped with a sophisticated temperature sensing system which protects it from any overheating
which may occur as a result of inadequate ventilation.
Note: Always ensure the dust lters behind the detachable front panel are clean to ensure maximum
possible airow.
3.4. Operating Voltage
The label adjacent to the mains (AC) input connector indicates the AC mains voltage for which the device is wired
and approved. Both PLM+ models incorporate a universal power supply operating from 80 to 265 V. Only connect
the mains cable (AC cord) to an AC source of the voltage shown on the label.
The PLM+ uses primary switching, which means the mains power is rectied on the primary side of the
transformer. This makes the power supply insensitive to mains frequency variation, and it will operate normally on
line frequencies from 45 to 75 Hz.