Table 7.6: Fault Conditions (Red LED)
Warning Type LED No.
On Screen
Warning Text
Event Log Text
Amp Ch Mute Channel 5-8 AMP CH. MUTE Amp Channel Mute
Amp Temp Fault Channel 5-8 TEMP FLT:CH Temp Fault: Amp Channel
Analog Input Fault Frame 1 ANALOG IN FAULT Frame Fault: Analog Input
Check AC Mains Frame 1 CHECK AC MAINS Frame Fault: Check AC Mains
Current Average Limiter Channel 5-8 CAL ACTIVE N/A
Current Protection Limiter Channel 5-8 CURRENT CLIP N/A
DSP Area Temp Fault Frame 1 TEMP FLT:DSP Temp Fault: DSP Area
Input Channel Mute Inp.Mix 2+3 INPUT MUTE Input Mute
Internal Audio Interface Fault Frame 1 AUDIO FAULT Frame Fault: Audio Interface
Module Input Mute Module 2+3 MOD. IN MUTE Module Input Mute
Module Output Clip Module 2+3 MOD. CLIP N/A
Module Output Mute Channel 5-8 MOD. OUT MUTE Module Output Mute
No Input Source Available Module 2+3 NO INPUT No Input Source
No Load Detected at Output Channel 5-8 NO LOAD Channel Fault: No Load Detected
Physical Input Clip Module 2+3 INPUT CLIP N/A
Power Average Limiter Frame 1 PAL ACTIVE N/A
Power Channel Failure Channel 5-8 SERVICE CH. Channel Fault: Unit Needs Service
PSU Area Temp Fault Frame 1 TEMP FLT:PSU Temp Fault: Power Supply Unit
PSU Fault / Undervoltage Frame 1 PSU FAULT Frame Fault: PSU Undervoltage
PSU Mains Over Voltage Peak Frame 1 MAINS > 400 VPK Frame Fault: PSU Mains > 400 VPK
PSU Mains Over Voltage RMS Frame 1 MAINS > 270 V Frame Fault: PSU Mains > 270 V
PSU Mains Under Voltage Frame 1 MAINS < 65 V Frame Fault: PSU Mains < 65 V
PSU Needs Service 1 Frame 1 NEEDS SERVICE: 1 Frame Fault: Needs Service: 1
PSU Needs Service: 2 Frame 1 NEEDS SERVICE: 2 Frame Fault: Needs Service: 2
PSU Needs Service 3 Frame 1 NEEDS SERVICE: 3 Frame Fault: Needs Service: 3
PSU Needs Service: 4 Frame 1 NEEDS SERVICE: 4 Frame Fault: Needs Service: 4
PSU Needs Service 5 Frame 1 NEEDS SERVICE: 5 Frame Fault: Needs Service: 5
PSU Needs Service: 6 Frame 1 NEEDS SERVICE: 6 Frame Fault: Needs Service: 6
PSU Needs Service 7 Frame 1 NEEDS SERVICE: 7 Frame Fault: Needs Service: 7
PSU Needs Service: 8 Frame 1 NEEDS SERVICE: 8 Frame Fault: Needs Service: 8
PSU Rail Protect Frame 1 PSU POWER PROT Frame Fault: PSU Power Protect
Short Circuit Protection Channel 5-8 SHORT CIRCUIT Channel Fault: Short Circuit Protection
Speaker Magnet Temp Fault Channel 5-8 TEMP FLT: MAG Temp Fault: Speaker Magnet
Speaker VC Temp Fault Channel 5-8 TEMP FLT: VC Temp Fault: Speaker Voice Coil
VHF Protection Channel 5-8 VHF FAULT Channel Fault: Very High Frequency
Voltage Protection Limiter Channel 5-8 VOLTAGE CLIP N/A
Wrong Type of Speaker Channel 5-8 WRONG LOAD Load Type / Routing Mismatch