Manual

7. Front Panel Interface
PLM+ SERIES Operation Manual rev 1.0.0
39
7.10. Meter Mode
7.10.1. Home View
The default view when powering on the device is Meter Mode > Home View as shown in Figure 7.7.
Figure 7.7: Meter Mode > Home View
Home View provides a summary of Module I/O gain level and limiter gain reduction, along with frame, module and
channel labeling information. The example in Figure 7.7 shows a mono 2-way, with Module A feeding power output
channels 1 & 2, and Module B congured as CL1-way feeding a subwoofer on power output channel 3.
Module C is congured for driving a full-range loudspeaker on power output 4. Module D is unused in this
example.
1
Module A label, input gain meter, faults, warnings, clips & mutes.
2
Module B label, input gain meter, faults, warnings, clips & mutes.
3
Module A label, input gain meter, faults, warnings, clips & mutes.
4
Module D label, input gain meter, faults, warnings, clips & mutes.
5
Module output label for Power channel 1, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
faults, warnings, clips & mutes.
6
Module output label for Power channel 2, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
faults, warnings, clips & mutes.
7
Module output label for Power channel 3, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
faults, warnings, clips & mutes.
8
Module output label for Power channel 4, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
faults, warnings, clips & mutes.
9
Menu Bar: Current View title & Frame label, Frame faults and warnings. The menu bar is located by default at
the top of the display, but can be congured in the front panel menu for placement at the bottom. The following
indications, as active or applicable, also are shown on the menu bar.
Ω - AES3 Input Terminated (no icon = Unterminated)
- Analog Inputs Iso-Float Grounded (no icon = Floating)
- Dante Clock Master (no icon = Dante Slave or Dante Disabled)
- Dante Slave Only (no icon = device may be used as Dante Clock Master)
REDUNDANT - Dual Redundancy networking enabled. (No icon = congured for switch mode)
Please refer to Table 7.5 and Table 7.6 for full details on the faults and warnings that could be displayed in any of