Owner manual

13. Quick Start Tutorial
16
PLM+ SERIES Quick Start Guide rev 1.0.0
13. Quick Start Tutorial
This section will describe how to get started with associated software and set up a basic system for operation.
13.1. Network setup
13.1.1. Network connections / topology
Each frame has two network ports; a primary and a secondary. See the below diagram for a typical network
topology using the primary ports.
By default, the secondary ports are congured in dual redundancy mode to support a second redundant network.
The alternate conguration for the two ports is a switch mode which allows daisy-chaining devices in a single
network. Daisy chain mode is not recommended for more than a few devices, and for not more than two if running
Dante audio along with control data.
Note: If using Dante audio in the network, the audio trafc needs to be ltered from reaching the
wireless links.
13.1.2. Network configuration
Frames are congured by default to obtain IP addresses automatically. The frame will assign itself an IP address
in the link local range (169.254.1.0 through 169.254.254.255). If a computer is congured the same way
(which should be default on modern operating systems), it will reside in the same subnet as the devices and
communication can be established. Alternate congurations would be DHCP for a managed network or xed IP.
To connect to the secondary network in dual redundancy mode the computer shall be congured with an IP
address in the 172.31.0.0 - 172.31.255.255 range.
Computer
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
PLM+ Series
Switch
Wireless
Access Point
Switch