PLM+ SERIES Quick Start Guide rev 1.0.0
Auto RPM:
The frame will automatically allocate power per output channel according to the ISVPL settings in the Lake module.
If the ISVPL settings taken together allow total output higher than the capabilities of the amplier, RPM will reduce
the ISVPL limiter thresholds evenly based on a proportional reduction in dB. When RPM is active, an RPM icon will
be displayed next to the “Actual ISVPL” values in the Events & Control section.
Custom RPM:
The Café software allows users to create an advanced custom power allocation scheme. Switching to Custom
mode disables the Automatic mode. When RPM is active an RPM icon will be displayed next to the “Actual ISVPL”
values in the Events & Control section. Please nd more information about this in the CAFÉ Operation Manual
CAFÉ with ESP: Integrated software for efcient project planning and fast system conguration
CAFÉ (Conguring Ampliers For the Environment) is a dedicated software application for Windows and OSX that
provides tools for system planning, specication and commissioning. CAFÉ improves work ow efciency at every
stage of the project, from initial design through bid tender and nal system optimization.
Windows 8