Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
106
Lake Controller Operation Manual Rev 1.5.9
EQ/Levels Menu Reference
EQ added to an Aux tab affects only the associated output. Module and Group input EQ (PEQ/BLEQ/GEQ)
still affects all outputs of the Module.
6.5.4 High-pass and Low-pass Filters
The high-pass and low-pass lter controls are located under the AUX OUTPUT FUNCTIONS submenu.
1. With the AUX-1 tab selected, tap AUX OUTPUT FUNCTIONS
2. Tap HPF ENABLE then tap LPF ENABLE
Figure 6-22: Aux Output with HPF and LPF Enabled
To adjust the slope of these lters:
1. Tap FILTER SELECT
A scroll bar appears displaying available HPF/LPF types.
2. Drag the scroll bar or use the << and >> buttons to view available lters.
3. Select the 24dB LINKWITZ/RILEY lter from the scroll bar.
4. Tap FILTER SET to activate this lter, then YES to the warning message.