Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.9
Modules Menu Reference
149
8.2.10.2 MAC Address
The MAC address is the unique Ethernet address of the selected device.
8.2 .10.3 Dante Slave Only (not applicable for MY8-LAKE)
If Dante Slave Only is Enabled, the device can only operate as a slave to the Dante network, and will not
be part of the Dante Clock Master selection process. It is recommended that this setting is enabled for all
devices unless the device is specically required to be part of the Dante Clock Master selection process.
This setting is enabled (ON) by default for Lake-enabled ampliers and disabled (OFF) by default for LM
Series devices. When running a Dante Dual Redundant system, it is recommended to have a few (2-6)
Lake-enabled ampliers with Dante Slave Only disabled.
This hardware parameter is unaffected by SYSTEM RECALL,
FRAME REPLACE, FRAME PRESET RECALL or FRAME
CONFIGURATION and SOFT RESET options. It can changed
only via this screen and via a front panel Factory Reset.
8.2 .10.4 Front Panel Enable (D Series only)
If Front Panel Enable is ON (orange), the front panel conguration functionality on the device will be active;
this functionality will be disabled if this button is OFF (blue).
This hardware parameter is unaffected by SYSTEM RECALL,
FRAME REPLACE, FRAME PRESET RECALL or FRAME
CONFIGURATION and SOFT RESET options. It can changed
only via this screen and via a front panel Factory Reset.
8.2 .10.5 Dual Redundancy (not applicable for MY8-LAKE)
This option activates dual redundant network capabilities for Lake Controller data and Dante audio. The
secondary Ethernet port has an IP address in the 172.31.x.x range. The power must be cycled on the Lake
device to complete the change.
The Dual Redundancy option can also be viewed and changed for all devices (except MY8-LAKE) via the
Global Control Tab.
This hardware parameter is unaffected by SYSTEM RECALL,
FRAME REPLACE, FRAME PRESET RECALL or FRAME
CONFIGURATION and SOFT RESET options.
This value can only be changed via the Technical Data screen, Global Control Tab, or via a the Factory Reset
option from the device front panel.