Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
150
Lake Controller Operation Manual Rev 1.5.9
Modules Menu Reference
8.2 .10.6 IP Address Cong
This eld is set by default to AUTO - ZERO CONF. It can also be set to AUTO - DHCP (if a DHCP server is
used) or to a FIXED IP ADDRESS. The power must be cycled on the Lake device to complete the change.
This hardware parameter is unaffected by SYSTEM RECALL,
FRAME REPLACE, FRAME PRESET RECALL or FRAME
CONFIGURATION and SOFT RESET options.
This parameter is changed only via this screen and via the FACTORY RESET option from the front panel of
the device.
8.2.10.7 IP Address
The Internet protocol (IP) address identies which device is sending or receiving information. The power
must be cycled on the Lake device to complete the change. For PLM+ and D Series devices, there is a
separate Dante module with it’s own IP address.
Both the Lake and Dante IP addresses must be on the same subnet to enable Dante conguration via the
Lake Controller, and to enable full rmware update of both components via the Lake Update Utility. If the IP
Address of the Lake component is set to a xed IP address, it is recommended that the Dante component is
changed to the Lake address + 1.
If the FIXED IP ADDRESS option is selected as described in 8.2.10.6, this eld becomes editable and an IP
Address may be entered manually.
This hardware parameter is unaffected by SYSTEM RECALL,
FRAME REPLACE, FRAME PRESET RECALL or FRAME
CONFIGURATION and SOFT RESET options.
This parameter is changed only via this screen and via the FACTORY RESET option from the front panel of
the device.
8.2 .10.8 Subnet Mask
The subnet mask is used for IP address routing; the default setting is 255.255.0.0 when
AUTO - ZERO CONF is selected. The power must be cycled on the Lake device to complete the change.
If the FIXED IP ADDRESS option is selected as described in 8.2.10.6, this eld becomes editable and an
Subnet Mask may be entered manually.
This parameter is unaffected by SYSTEM RECALL, FRAME PRESET RECALL or soft FRAME RESET
options. It is reset only via the FACTORY RESET option from the front panel of the device.