Groups Menu Reference
10.7.1 Gang Xover/Aux or Gang HPF/LPF
This button read GANG XOVER/AUX when a Group containing Contour Modules is selected, and GANG
HPF/LPF when a Group containing Mesa EQ Modules is selected. These functions allow the crossovers,
auxiliary output channels, and HPF/LPF settings of Modules on different Frames to be linked together.
When GANG XOVER/AUX is active on a Group containing crossover Modules, the crossovers, HPF/LPF,
and auxiliary channels of all Modules in the Group are synchronized. A change made in one Module will
be reected in all Modules of that Group.
When Gang HPF/LPF is active on a Group containing Mesa EQ Modules, the HPF/LPF will be linked on
all Modules in the Group.
To gang the crossover or HPF/LPF of all Modules in a Group, perform the following steps:
1. Assign the Modules to a Group. All Modules must be of the same crossover type, such as Classic
3-Way (CL3way), for example.
All Modules must be of the same Module type,
such as a Classic 3-Way (CL3way), for example.
2. From the GROUPS menu, tap GANG.
3. Tap the Module on the scroll bar to select which Module’s settings will be transferred to all other
Modules in the Group.
4. Tap GANG XOVER/AUX (Contour Modules) or GANG HPF/LPF (Mesa EQ Modules).
5. Tap YES to the warning message.
Only the XOVER/AUX/HPF/LPF and associated
OUTPUT EQ data is ganged. LEVELS data and
INPUT EQ (PEQ/BLEQ/GEQ) cannot be ganged. Use
Group EQ/LEVELS to control multiple Modules.
To synchronize all data across multiple Modules,
you can use the powerful SUPER MODULE
feature. Refer to section 8.8 for details.
10.8 Add Page
The ADD PAGE function is always available from the GROUPS menu and creates additional pages that help
manage large systems with many Module and Group icons.