Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.9
Designer Mode Menu Reference
241
19.3.4.2 Lock and Password-Protect a Module or Base Conguration
Locking a Module or base conguration enables access security (such as hiding EQ overlays, setting XOVER
screens to View Only, and disabling level functions). The LABEL & LOCK function activates security in both
User Mode and Designer Mode, allowing certain settings to be protected from other system designers.
From the Modules menu, tap a Module icon to select it.
1. Tap LABEL & LOCK.
2. Tap SET MOD PASSWORD (for Module) or SET BASE PASSWORD (for base Module).
3. Enter a password, and tap OK.
4. Conrm password, tap OK, then tap OK to the warning message.
5. Tap MODULE UNLOCKED or BASE UNLOCKED to lock the relevant settings.
19.3.4.3 Unlock a Locked Module or Base Conguration
From the MODULES menu, tap a Module icon to select it.
1. Tap LABEL & LOCK.
2. Tap UNLOCK MODULE or UNLOCK BASE.
3. Enter the associated password, and tap OK.
19.3.4.4 Creating Descriptions/Assigning Graphics for Module Files
Text les (.txt) and bitmap les (.bmp) with the same le name as a Module le can be placed in
My Documents\Lake\LakeController_vX.XX\Modules folder.
When a text le is present with the same le name, the Controller displays the text when the Module le is
selected on the MODULE STORE/RECALL scroll bar. When a bitmap le is present, the Graphic is displayed
in place of the default Module icon.
Bitmap les must be 24-bit Microsoft Windows
format with a dimension of 80×80 pixels. MODULE
LABEL text will overwrite the bottom portion of the
bitmap.
Follow these steps to create and view Module le descriptions:
1. Store a Module with the le name ’example’ at the Modules root directory.