Lake Controller Operation Manual

Table Of Contents
Lake Controller Operation Manual Rev 1.5.9
Lake-enabled Amplier Reference
251
20.2 Monitoring & Control
Many basic operating parameters are available in both the Lake Controller software and on the front panel
(except for D Series). These include, for example, gain adjustment, monitoring of output levels and tempera-
tures, and power control.
Basic per-channel operating parameters and gain adjustments are presented in the Status tab, with certain
adjustments and power control accessed via the Control tab. The History and Events tabs provide both
real-time log data and a Graphical representation of the amplier’s performance.
20.3 Lake LoadLibrary
In addition to the standard loudspeaker preset Module les, the Lake LoadLibrary includes a set of enhanced
les specically for use with Lake-enabled ampliers. These Module les provide parameter settings for
Amplier Gain and ISVPL
limiter.
Some Lake LoadLibrary loudspeaker types may include electrical characteristics data for the associated
loudspeaker. The data set relating to the loudspeakers electrical characteristics is used to enable load
verication (LoadSmart
) to be performed. This data set is termed a Fingerprint. When Lake-enable ampli-
er loudspeaker type is recalled, its Fingerprint load characteristics are included. These load characteristics
are stored in a le with a “.mdl” sufx and are recalled simultaneously with the Module le.
Lake LoadLibrary Modules can be recalled into any Lake-enabled device. Certain data such as ISVPL,
Amplier Gain and Fingerprint information is ignored when a Module is recalled into a device that does not
support these features.
Custom RPM parameters are stored in System les
and Frame Presets; these settings are not stored in
Module les.
20.4 LoadSmart™
LoadSmart is Lab.gruppen’s exclusive system for verifying the load connected to each output channel of
the amplier. LoadSmart is set up and run from the LoadSmart Tab. The number of each type of cabinet
that should be connected to each power channel can be specied, along with cable lengths, resistance, etc.
LoadSmart evaluates the load characteristics on each power output channel and either conrms them as
correct or reports if they are exhibiting anomalies.
LoadSmart is available when a Module with an associated Fingerprint le is loaded; check the Lake Load-
Library release notes to conrm which speaker presets have an associated Fingerprint le. Please refer to