Lake Controller Operation Manual

Table Of Contents
270
Lake Controller Operation Manual Rev 1.5.9
Lake-enabled Amplier Reference
20.12.3.1 Severity
Recorded events are divided into three categories: FAULTS, WARNINGS and USER ACTIONS. Events in any
or all of these categories may be displayed in the log by tapping the three buttons in the SEVERITY box. The
ALL button restores the default state of all three categories being selected.
20.12.3.2 Source
Using buttons in the SOURCE box, events may also be ltered on the basis of which part of the system
generated them. Any or all of six event sources may be selected, as follows:
Loudspeaker Identication
Loudspeaker Temperature
Amplier Device
Amplier Output
Other: Audio distribution
Other: Network
The ALL button restores the default state of all six categories being selected.
20.12.3.3 Time
It is possible to display only events which have occurred within a user-dened time interval, using the
buttons in the TIME box. The options are:
SINCE HH:MM – Tapping the HH and MM buttons opens a numeric keypad to allow a ‘Start time’ for
displayed events to be entered. Tapping the SINCE button activates the option.
LAST POWER CYCLE – Tapping this button causes the Event Log to only display events which have
occurred since the last time the was powered up.
20.13 Global Control Tab
The GLOBAL CONTROL tab is the second of two tabs available in AMPLIFIER GLOBAL VIEW.
To access AMPLIFIER GLOBAL VIEW:
1. Select the ALL page.