Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.9
LM Series Reference and Operation
281
21.3.3 Global Power Control
Two buttons, ON and STANDBY, control the power status of all devices (except MY8-LAKE) that are online
and present in the current system conguration. A conrmation is required prior to changing this status
across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators to the right of the buttons show the total number of devices in the current system congu-
ration that are ON, in STANDBY or OFFLINE.
21.3.4 Global Dual Redundancy Control
Two buttons, ON and OFF, control the Dual Redundancy network status of all devices (except MY8-LAKE)
that are online and present in the current system conguration. A conrmation is required prior to changing
this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators summarize the number of online devices in the current system conguration that have this
status set to ON or OFF.
The power must be cycled on the device for this
parameter change to complete. (i.e. Disconnect or
turn off mains power then reconnect or turn on
mains power).
Please refer to section 8.2.10.5 for further information regarding Dual Redundancy.
21.3.5 Global Dante Enabled Control
Two buttons, ON and OFF, control the Dante Enabled status of all devices (except MY8-LAKE) that are
online and present in the current system conguration. A conrmation is required prior to changing this
status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status. Status indicators summarize the number of online devices in the current system
conguration that have this status set to ON or OFF.
Two additional buttons, 48 kHz and 96 kHz control the Dante sample rate for all Dante-enabled devices in
the current system conguration.