Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.9
LM Series Reference and Operation
283
▸ Super Module View lters the results to show events that apply to all Modules in the Super Module.
▸ Global View displays all results for all devices in the system conguration.
The data set for the most recent event is repeated in
the separate horizontal pane at the bottom of the
table.
21.3.7.1 Log Entries
Seven items of information per event are displayed in the log in tabular form, as follows:
▸ EVENT – Displays system faults or warning notications. Icons shown below reference the source of
the notication. Icons change color, from yellow (warning) to red (fault) to indicate severity.
▸ START TIME – Displays the system time and date at which the event occurred
▸ DURATION – Displays ACTIVE while the fault/warning is active. Once the fault/warning becomes
inactive, the duration for which it was active is displayed. Once the event is cleared, its line of text in
the log changes color from white to gray.
▸ FRAME – Identies the Frame in which the fault/warning/event occurred by displaying the Frame label.
If a Frame label has not been allocated, this eld displays the default product model name i.e. LM 26.
▸ MODULE – Displays the name of the Module in which the event occurred. This will be the default
name if the Module has not been renamed (i.e. CL3way, 2aux, etc.).
▸ CHANNEL – Indicates the channel on which the event occurred. This column will be blank if the event
was a Frame event – e.g. network failure, etc.
▸ DESCRIPTION – Displays a description of the event. A full list of the possible warning messages can be
found in the product Operation Manuals.
21.3.7.2 Sorting Options
The default listing order for the data displayed in the event log is chronological, with the most recent event
at the bottom of the list. To sort the data by another column, tap the button at the top of the required
column.