Operation Manual

7. Front Panel Interface
PLM+ SERIES Operation Manual rev 3.0.4
43
Note: Output limiter (gain reduction) meters take into account the sum of PLM+ ISVPL and Lake
LimiterMax.
10
l to which each module output is routed. When
mode or Bridge Mode, as shown in Figure 7.8 For further information on Bridge Mode, please refer to section
8.1.1.
Figure 7.8: Standard and Bridge Mode Front Panel Icons (only for PLM 12K44 and PLM 20K44)
Bridge Mode is visible via this icon notation on the PLM+ Front Panel in Home View, however, the Lake Controller
information.
7.10.2. Amplifier Meters View
shown in Figure 7.9.
1
Output 1: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
2
Output 2: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
3
Output 3: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
4
Output 4: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
5
LoadPilot Status: 1. High Freq Pilot tone Enabled/Disabled, 2. Low Freq Pilot tone Enabled/Disabled, Status
7. Front Panel Interface
44
PLM+ SERIES Operation Manual rev 3.0.4
6
LoadPilot Status: 1. High Freq Pilot tone Enabled/Disabled, 2. Low Freq Pilot tone Enabled/Disabled, Status
7
LoadPilot Status: 1. High Freq Pilot tone Enabled/Disabled, 2. Low Freq Pilot tone Enabled/Disabled, Status
8
LoadPilot Status: 1. High Freq Pilot tone Enabled/Disabled, 2. Low Freq Pilot tone Enabled/Disabled, Status
9
Current View title & Frame label, Frame faults and warnings
The Voltage Meter (V) indicates the power output stage voltage relative to its clip level
The Current Meter (I) indicates the current the power output stage is driving into its load, relative to the
maximum permissible current the xed CPL allows
The Power Meter (P) indicates the instantaneous output power being developed in the load relative to the
PLM+s maximum output power capability.
The Gain Reduction Meter (L) indicates the degree of limiting being applied by the PLM+ ISVPL and/or the Lake
LimiterMax.
7.10.3. Temperature View
Temperature View provides information about the current operating temperatures within the PLM+. Selected fuse
type, as well as Mains Voltage and Current draw.
Figure 7.10: Meter Mode > Temperature View
1
Current View title. Power supply temp (PSU) & Lake processor temp (DSP) as percentage of maximum
2
Unused in Temperature View
3
Unused in Temperature View
4
Breaker Emulation Limiter; selected Fuse type - Mains Voltage - Mains Current Draw
5
Output 1: AMP - Temp of power output as percentage of maximum
6
Output 2: AMP - Temp of power output as percentage of maximum
7
Output 3: AMP - Temp of power output as percentage of maximum
8
Output 4: AMP - Temp of power output as percentage of maximum
9
Current View title & Frame label, Frame faults and warnings
7. Front Panel Interface
45
PLM+ SERIES Operation Manual rev 3.0.4