7.11.5.3. Breaker Emulation Limiter
MENU > FRAME > BEL CONF
The Breaker Emulation Limiter (BEL) provides Ampere selection (5-32 A) and breaker type selection
(CONSERVATIVE, FAST and UNIVERSAL). Select by pressing the adjacent button then use the rotary encoder to
change the parameter.
7.11.5.4. Network
MENU > FRAME > NETWORK
parameters (except Redundancy) are view-only on the front panel and are either not editable, or can only be
adjusted via the Lake Controller.
and whether the Lake Controller is online.
IP Addr: Displays the Internet Protocol address for the selected unit and can only be changed via the Lake
Controller software. Please refer to the Lake Controller Operation Manual for further details.
MAC: Displays the unique Media Access Control Ethernet address for the processor. This value cannot be
changed.
Primary and Secondary network connection status as well as Lake Controller connection status
Mask: Displays the IP address subnet mask for the selected unit and can only be changed via the Lake
Controller software. Please refer to the Lake Controller Operation Manual for further details.
ro Conf, Auto - DHCP or Fixed IP)
Redundancy: Displays the dual redundancy status for the Frame (ON/OFF) This mode can be changed by
een. Changing redundancy mode
requires a power cycle to activate.
7.11.5.5. Latency Match
To turn Latency Match on or off, select the parameter using the adjacent button then change the status using the
rotary encoder.
By default, PLM+ products exhibit the exact same input-to-output latency as the PLM and D Series products.
However, the PLM+, PLM and D Series products have a greater latency compared to the Lake processors of LM
Series. By enabling the Latency Match feature, the LM Series will add delay to match overall processing delay of
the PLM, PLM+, and D Series. This regards Analog and AES only. Dante is not part of Latency match.
Exception: Latency match will not function correctly when running 48k based AES input using the primary clock
domain.
The maximum RMS input current varies, and therefore a desired value is configured and the actual
value is displayed within brackets.
7. Front Panel Interface
58
PLM+ SERIES Operation Manual rev 3.0.4
7.11.6. Front Panel Display Controls
MENU > FRAME > FRONT
Contrast
To adjust the front panel LCD contrast, select this option then use the rotary encoder to change the value.
Dimming
To adjust the front panel LCD & LED brightness, select this option then use the rotary encoder to change the value.
Channel Order
To adjust the order in which both inputs and outputs are displayed on the front panel in all views, select this option
then use the rotary encoder to change the value between TOP-DOWN (default) and BOTTOM-UP.
7.11.7. Frame Preset Menu
MENU > FRAME PRST
To recall an existing Frame Preset, use the rotary encoder to select the required Preset then press the RECALL
button to overwrite the current conguration.
Note: Frame Presets must initially be created in the Lake Controller, and stored as a Preset using the
Lake Controller or the PLM+ Series Preset Manager.
Up to 100 Frame Presets can be stored in the device. The data within a Frame Preset includes the conguration
of all Modules in the Frame including levels, crossovers, EQ, input mixer, and output routing. (Note that Network
settings and the Dual Redundancy setting are not part of Frame Presets.)
As Frame Presets are stored within the device, complete processor congurations can be recalled without
connecting the device to a PC.
7.11.8. Load Monitor Menu (LoadSmart)
MENU > LOAD MON
Figure 7.22: LoadSmart Verication Results Screen
7. Front Panel Interface
59
PLM+ SERIES Operation Manual rev 3.0.4