Operation Manual

7. Front Panel Interface
PLM+ SERIES Operation Manual rev 3.0.4
59
7.11.8.1. Configure # of Cabinets in Parallel
This option allows selection of the number of speaker cabinets connected to each PLM+ output channel. Select
individual or multiple outputs and use the rotary encoder to set the value from 1 to 4. This value is used by
LoadSmart to conrm the correct connection and status of the speakers connected to each PLM+ channel.
7.11.8.2. LoadSmart Verification
Select this option to initiate LoadSmart verication, then select YES to continue. LoadSmart performs a rapid test
of all output channels, and displays the results on the LCD a few seconds later.
Figure 7.23: LoadSmart Verication Results Screen
The Load Results page provides three items of information per output channel:
Conrmation that the speaker connected matches the speaker ngerprint assigned to the channel. If no
Fingerprint is assigned, NO MODEL will be displayed. If the wrong speaker is connected; “Wrong Speaker”
will be displayed
Result of speaker cabinet count; this will either be OK or WRONG.
Estimated number of speakers connected to the channel.
8. Back Panel Interface
60
PLM+ SERIES Operation Manual rev 3.0.4
8. Back Panel Interface
An overview of the back panel interface is provided in section 4.2. This chapter describes each cluster of
connections as shown in Figure 8.1.
INPUT 1 INPUT 2 INPUT 3
AES/EBU
INPUT 1-2 INPUT 3-4
SECPRIM
Must be grounded/earthed
Made in Sweden
PIN 1: SCRN 2: POS 3: NEG
ANALOG WITH
I
SO-
F
LOAT
TM
50-60Hz
100-240V 2400-2950W
Ser. N:o
Removed!
CH 2
CH 1
CH 4
CH 3
SPEAKER OUTPUTS
CLASS 3 WIRING
BRIDGE
BRIDGE
INPUT 4
SWITCHED 00/ 000 Base-TX11
1Gbps 1Gbps
LINK
ACT
LINK
ACT
PLM 2K44
1
1+/- CH 1+/-
2+/- CH 2+/-
1+/- CH 1+/-
2+/- CH 2+/-
3+/- CH 3+/-
4+/- CH 4+/-
1+/- CH 3+/-
2+/- CH 4+/-
CLASS 3
WIRING
BRIDGE CH 1 & 2:
1+:+
2- : -
BRIDGE CH 3 & 4: 1+ : +, 2- : -
SPEAKER OUTPUTS
INPUT 1 INPUT 2 INPUT 3
AES/EBU
INPUT 1-2 INPUT 3-4
SECPRIM
Must be grounded/earthed
Made in Sweden
PIN 1: SCRN 2: POS 3: NEG
ANALOG WITH ISO- F LOAT
TM
50-60Hz
100-240V 2400-2950W
INPUT 4
SWITCHED 00/ 000 Base-TX11
1Gbps 1Gbps
LINK
ACT
LINK
ACT
PLM 2K44
1
Figure 8.1: Back Panel Interface
8.1. Speaker Outputs
The PLM+ is available with either 4 mm binding posts or Neutrik speakON connectors for the outputs.
The outputs of the PLM+ can produce a high voltage. Do not connect or disconnect loudspeaker/s while the
PLM+ is powered on. Never operate the PLM+ with any portion of bare loudspeaker wire exposed.
For speakON connector versions, do not use mating plugs without the rear covers in place.
8.1.1. Bridge Mode
NOTE: When Bridge Mode is activated, CLASS 3 wiring is required.
Power outputs may be bridged on PLM 12K44 and 20K44 models by following the configuration instruction in the
Lake Controller Operation Manual (I/O CONFIG > OUTPUT CONFIGURATION) and the wiring instructions in this chapter.
Bridge Mode can only be activated/deactivated using the Lake Controller software.
INPUT 1 INPUT 2 INPUT 3
PIN 1: SCRN 2: POS 3: NEG
ANALOG WITH ISO-FLOAT
TM
INPUT 4
Ser. N:o
Removed!
AES/EBU
SWITCHED 00/ 000 Base-TX11
INPUT 1-2 INPUT 3-4
SECPRIM
1Gbps 1Gbps
LINK
ACT
LINK
ACT
PLM 5K44
CH 2CH 1
SPEAKER OUTPUTS
CH 2CH 1
1+/- CH 1+/-
2+/- CH 2+/-
1+/- CH 2+/-
CH 4CH 3
CH 4CH 3
CLASS 2
WIRING
1+/- CH 3+/-
2+/- CH 4+/-
1+/- CH 4+/-
Must be
grounded/
earthed
50-60Hz
100-240V
2400-2950W
8. Back Panel Interface
61
PLM+ SERIES Operation Manual rev 3.0.4