18. Tap the Input Gain button in the block diagram and unmute the Module Input Mute. Tap EQ/Levels Exit to return to
IO Con g.
19. The left side of the IO con g screen holds frame con guration and summary for Clock con guration, Input
con guration, Dante con guration, Breaker Emulation Limiter con guration and Analog Iso-Float & AES Termination
con guration. All these con gurations should be correct by default for this example.
20. From I/O CONFIG, tap EVENTS & CONTROL and navigate to the STATUS tab. If muted, unmute the power
channels and slowly increase the volume on the appropriate feed from the mixing console. Audio should now be
active at the outputs and heard through the loudspeakers. Close the Events and Control dialog with the return
button and return to the main area by tapping the I/O Con g EXIT button.
Levels Control - Drag sliders and tap mute buttons for module
input and output channels.
Delay Control - Drag sliders to control input and output delay Crossover control – Select lters and drag on the bottom
frequency bar to adjust crossover frequency. Crossover
types may be changed by selecting the Crossover
Functions button.
Parametric EQ control – Select lter on the top squares
and adjust lter properties by dragging the controls. Sliders
at the bottom control center frequency and Q (bandwidth).
Gain is controlled in the main window area. Additional lters
can be added by tapping the top lter objects and placing
new lters on the main area.
Events & Control, Status tab – Drag sliders to adjust power channel attenuation and tap mute buttons to
control power channel mute. Metering and Status monitoring is available for each power channel.