User's Manual

52
TroubleshooTInG
When in doubt !
Many issues can be resolved by powering the unit off and then back on again or by
resetting to factory default settings. Before proceeding to any other troubleshooting
procedure follow these steps:
1. Set power to OFF
2. Wait 10 seconds or until display completely blanks
3. Set power to RECEIVE or TRANSMIT
Reset to Default Factory Settings
1. Set power switch to OFF
2. Press and hold C key
3. Continue to hold C and set the power switch to either RECEIVE or TRANSMIT
4. Release C key when CLEAR/RESET message appears
Default factory settings are as follows:
Channel
17
Display Contrast
Medium
Transmitter Zones
A B C D L all enabled
Delay Time
0.0100 sec
Receiver Zone
A
Equalize Calculated Time
0.1500 sec
Relay Mode
OFF
Interval Time
00:00:01
Operating mode
NORMAL
Multipop Time
1.00 sec
Contact Time
0.08 sec
Counter Mode
OFF
Beep Mode
All
Counter Load
36
Fast Mode
OFF
N
Ihe following indicators may operate erratically during reset, but will return to normal
operation when reset completes: Battery Level, Frequency Lock, Beep Mode, and Channel.
The CLEAR/RESET message also displays the software version installed in the unit. To
view just the software version without losing settings refer to the Software Version
Display section, Page 39, for more information.