Instruction Manual

10
Chapter 3: Getting Started
Product Service 1-800-522-7658, International 816-333-8811
Connect to the Blower Inlet for
Fiberglass Blowers
Fiberglass Blowers, model numbers 7180000 through 7180700,
feature a 10-3/8" OD inlet ring. This inlet ring is suitable for use
with 10-inch diameter PVC ductwork. The PVC ductwork will fit
outside the inlet ring and should be fastened by sheet metal screws
through the fiberglass inlet ring. A silicone sealant is to be used to
seal between the ductwork and the blower inlet ring to prevent air
or moisture leakage.
Fiberglass Blowers model numbers 7180800 through 7181700,
feature 12-3/8" OD inlet ring, which is suitable for use with 12-
inch diameter PVC ductwork. The 12-inch diameter PVC
ductwork will fit over the inlet ring on the blower and fastened by
sheet metal screws through the fiberglass inlet ring.
Fiberglass Blowers, model numbers 7182000 through 7182300,
feature a 15-5/8" OD inlet ring, which is suitable for use with 16-
inch diameter PVC ductwork. The 16-inch diameter PVC
ductwork will fit over the inlet ring on the blower and fastened by
sheet metal screws into the fiberglass inlet ring.
Connect to the Blower Inlet for
PVC Blowers
PVC Blower model number 7183000 features a 10-3/8" OD inlet
ring. This inlet ring is suitable for use with 10-inch diameter PVC
ductwork. The PVC ductwork will fit outside the inlet ring
through the PVC inlet ring. A silicone sealant should also be used
to seal between the ductwork and the blower inlet ring to prevent
air or moisture leakage.
PVC Blowers model numbers 7183100 and 7183200, feature a 12-
3/8" OD inlet ring, which is suitable for use with 12-inch diameter
PVC ductwork. The 12-inch diameter PVC ductwork will fit over
the inlet ring on the blower and should be fastened in position by
sheet metal screws into the fiberglass ring.
FRP