Instruction Manual

37
Product Service 1-800-522-7658, International 816-333-8811
Chapter 7: Modifying Your Blower
Nominal Diameter/Inches
6
8
10
12
16
Actual OD/inches
6.625
8.625
10.750
12.750
16.000
Actual ID/inches
6.25
8.250
10.375
12.375
15.625
Catalog Number
47086
47189
70272
56020
56050
Shipping Wt./lbs.
20
35
50
65
80
Airflow/CFM
Static Pressure Loss/Inches H
2
0
For Each 10 ft. of Duct Length
250
.039
.011
.003
.001
--
500
.147
.037
.013
.005
.001
750
.321
.079
.026
.011
.003
1000
.557
.140
.043
.018
.005
1250
.855
.210
.066
.027
.008
1500
--
.300
.095
.039
.012
1750
--
.380
.130
.053
.016
2000
--
.485
.155
.067
.020
2500
--
--
.245
.109
.031
3000
--
--
--
.145
.042
4000
--
--
--
.240
.074
5000
--
--
--
--
.120
Thermoplastic Duct
PVC exhaust duct is Type 1, unplasticized, schedule 40,
lightweight and corrosion-resistant. A female duct coupling is
required to join two sections. Connections are simple with solvent
cement. This rigid duct may be cut without special tools. Comes
in 10' lengths.
Nominal Diameter/Inches
6
8
10
12
16
Catalog Number
47086
47189
70272
56020
56050
Actual OD/inches
6.625
8.625
10.750
12.750
16.000
Actual ID/inches
6.250
8.250
10.375
12.375
15.625
Shipping Wt./lbs.
25
35
50
65
80
Duct Couplings, Female
PVC coupling makes connection between two sections of
thermoplastic duct quick and easy.
Nominal Diameter/Inches
6
8
10
12
16
Catalog Number
47089
47192
70275
56023
56053
Shipping Wt./lbs.
4
5
5
6
7
Equivalent Resistance in Feet
of Straight Duct
0
0
0
0
0