SETUP
Adjusting Fluid Flow
1 Remove the neck skin.
2 Locate the restrictor valves in the left and right clavicle area.
3 Activate secretion in the Circulation and Fluids Tab, then tighten
or loosen the actual valve as until desired flow rate is achieved.
Note: Do not unscrew completely. Please note that only slight
adjustment should be necessary.
4 Replace the neck skin.