TP-100 User Guide Copyright Notice All contents of this manual, whose copyright belongs to our Corporation cannot be cloned, copied or translated without the permission of the company. Product specifications and information which were referred to in this document are for reference only. We may change, delete, or update any content at any time and without prior notice. =================================================================================== This is class A production.
Catalog 1 Packing List ......................................................................................... 1 2 About Product ...................................................................................... 2 2.1 Product Appearance .................................................................................. 2 2.2 Product Specifications ............................................................................... 4 3 Installation Connection ................................................
1 Packing List When unpacking, please check and confirm all accessories that should be provided. HD Video Conference Terminal x 1 Power Adapter x 1 Remote Control x 1 RJ45 to DIN8 Control Cable x 1 HDMI Cable x 2 Quick Start x 1 User Guide x 1 CD x 1 Microphone x 1 Copyright © 2021 Laia · www.laiatech.
2 About Product Laia TP-100 video conference terminal adopts embedded system design and supports 1080P HD codec and H.323 and SIP communication protocols. Split-type design, easy to install, connect to the network, microphone, TV, plug in the power to communicate. The voice and image information are transmitted to each other to complete various conference functions such as document sharing.
No. Name 7 AUDIO OUT Function The lotus head audio output interface connects the speaker and terminal through the audio cable to output sound. The lotus head audio input interface connects to the audio 8 AUDIO IN input devices such as microphones, mixers, etc. SDI output interface for connecting a coaxial cable to the SDI 9 SDI OUT output interface. SDI input connector for connecting a coaxial cable to the SDI 10 SDI IN input interface.
2.2 Product Specifications Category Item Specifications Operating Voltage AC 100V ~ 240V Power Consumption 20W (Max) Electrical Feature Working Status Temperature 0°C ~ 40°C Relative Humidity 10% ~ 80% Ambient Noise < 46dBA SPL Environmental Requirements Non-working Status Temperature -40°C~70°C Relative Humidity 0%~95% Dimension 200mm x 428mm x 44.5mm Net Weight 3.2kg Physical Feature Copyright © 2021 Laia · www.laiatech.
3 Installation Connection The terminal can be installed in the cabinet or placed directly on the horizontal desktop. If you place the terminal directly on the desktop, keep the desktop steady and pay attention to the anti-slip. If you place the terminal in a rack, use screws to secure it to the rack. Adjust the orientation of the terminal to avoid facing bright light sources (such as windows). It is recommended that the terminal be facing the participant. 3.
Input microphone sound: Use the CANNON cable to connect the matching microphone to the MIC IN interface of the terminal. Input the player sound: Use the Lotus head audio cable to connect the computer or phone audio to the AUDIO IN interface of the terminal. Output sound: Connect the HDMI OUT1 of the terminal to the HDMI input of the display device using the HDMI cable, or connect the audio (speaker) to the AUDIO OUT interface of the terminal using the Lotus head audio cable.
Indicator Status Status Description Power Indicator (green and bright) Normal work Power Indicator (off) Power has been disconnected Infrared receiving indicator (flashes green) Received remote infrared signal 4 Remote Control Copyright © 2021 Laia · www.laiatech.
5 GUI Main Interface Press the home key “ ” of the remote control to enter the GUI main interface. No. Description No. Description No.
6 Basic Settings 6.1 Network Settings Step 1 Enter the GUI main interface, select “Settings > Network > IPv4”. Step 2 Set network parameters such as IP address, gateway and subnet mask etc. Step 3 Select “Save”, save configuration information. Step 4 End.
6.2 H.323 Account Settings (optional) Set the H323 ID and number of the terminal, specify the GK address, and enable the terminal to register with the GK, so that the conference or other terminal can be called by the number. Step 1 Enter the GUI main interface, select “Settings > Account > H323 Account”. Step 2 Configure H323 account parameter information. The parameters are described in the following table. Step 3 Select “Save”, save configuration information. Step 4 End. Parameter Description Enable H.
Parameter Description Enable or disable register GK function, the options are: Enable: The terminal registers with the GK server. After the terminal is successfully registered to the GK server, you can call other Register GK terminals through the remote meeting number. Disable: The terminal does not register with the GK server. When calling with the H.323 protocol, only other terminals can be called by IP address. Set the IP address or domain name of the GK server.
Parameter Description Enable SIP Enable or disable SIP function. Select the SIP account register mode, you need to manually enter the Register Mode information required for SIP registration. Enable or disable register SIP function, the options are: Enable: The terminal registers with the SIP server. After the terminal is successfully registered to the SIP server, you can call other Register SIP terminals through the remote meeting number.
Parameter Description Username Enter the username used to register the SIP server. Authentication Enter the username used for authentication. Username Authentication Enter the domain name used by the SIP server to identify the Realm corresponding domain. Enter the password of the SIP server to be used by the terminal to Authentication authenticate the terminal of the SIP server.
6.5 Date Settings Step 1 Enter the GUI main interface, select “Settings > System > Date”. Step 2 Set parameters such as date, time, and date format. Step 3 Select “Save”, save configuration information. Step 4 End. Parameter Description Enable “Automatic date & time” to indicate the time provided by Automatic date time the network. Set date Set the date to take effect when disable “Automatic date time”. Set time Set the time to take effect when disable “Automatic date time”.
6.6 Reset Settings Step 1 Enter the GUI main interface, select “Settings > System > Reset”. Step 2 Select “Reset to factory settings”. Step 3 Select “Save”, save configuration information. Step 4 End. After restoring the factory settings, all the terminal parameters you configured earlier will be lost, please be careful settings! Copyright © 2021 Laia · www.laiatech.