12.3 Approved Antenna List
The following antennas are approved for use with the AC4490 as identified. The OEM may choose another vendor’s antenna
of like type and equal or lesser gain as a listed antenna and still maintain compliance.
Table 8: AC4490 Approved Antennas (for revision 1.0 hardware)
Laird
Part #
Manufacturer
Part #
Manufacturer
Type
Gain
(dBi)
200M
1000M
0600-00019
S467FL-5-RMM-915S
Nearson
1/2 Wave Dipole
2
X
X
0600-00025
S467FL-5-RMM-915
Nearson
1/2 Wave Dipole
2
X
X
0600-00024
S467AH-915S
Nearson
1/2 Wave Dipole
2
X
X
0600-00027
S467AH-915R
Nearson
1/2 Wave Dipole
2
X
X
0600-00028
S161AH-915R
Nearson
1/2 Wave Dipole
2.5
X
X
0600-00029
S161AH-915
Nearson
1/2 Wave Dipole
2.5
X
X
0600-00030
S331AH-915
Nearson
1/4 Wave Dipole
1
X
X
-
1020B5812-04 Flavus
gigaAnt
Microstrip
-0.5
-
-
-
Y2283
1
Comtelco
Yagi
6dBd
X
X
-
Y2283A0915-10RP
Comtelco
Yagi
6dBd
X
X
-
SG101N915
1
Nearson
Omni
5
X
X
-
SG101NT-915
Nearson
Omni
5
X
X
-
GM113
V.Torch
Omni
3.5
X
-
-
PC8910NRTN
Cushcraft
Yagi
11dBd
-
-
-
ANT-DB1-RMS
Antenna Factor
Monopole
3
X
-
1. Strictly requires professional installation.
Table 9: AC4490 Approved Antennas (for revision 2.0 hardware for -1000M)
Laird
Part #
Manufacturer
Part #
Manufacturer
Type
Gain
(dBi)
1000M
0600-00019
S467FL-5-RMM-915S
Nearson
1/2 Wave Dipole
2
X
0600-00025
S467FL-5-RMM-915
Nearson
1/2 Wave Dipole
2
X
S467AH-915
Nearson
1/2 Wave Dipole
2
X
0600-00024
S467AH-915S
Nearson
1/2 Wave Dipole
2
X
0600-00028
S161AH-915R
Nearson
1/2 Wave Dipole
2.5
X
0600-00029
S161AH-915
Nearson
1/2 Wave Dipole
2.5
X
12.4 FCC Requirements for Modular Approval
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures: