User's Manual

Section 5, Page 2 01/2001, CATTRON
- THEIMEG
TM
Installing Different PSCS (blue) & EZ (green) ‘i-Keys’, continued.
If you wish to continue remote control operations, it will be necessary to choose one of the following
options:
1. Install the original ‘i-Key’ into the controller,
or,
2. Re-program the address code and frequency of the controller with a different ‘i-
Key’ installed refer to page 5 of this Section onwards for programming
procedures. This unique ‘i-Key’ serial number will then be registered with the host
controller’s programming software immediately upon entering one of the
controller’s keypad programming menu options.
NOTE. If option 2 above has been selected, inserting the original ‘i-Key’ (referred
to in option 1 above) or any other ‘i-Key’ into the controller will prevent
any further remote control operations.
PSEZ & CS Control Systems - frequency and address
assignment.
WARNING:
FAILURE TO PROPERLY SELECT FREQUENCY AND
ADDRESS MAY RESULT IN THE UNINTENTIONAL
OPERATION OF OTHER MACHINERY AND COULD RESULT
IN DEATH OR SERIOUS INJURY TO PERSONNEL. DO NOT
DUPLICATE ADDRESS ASSIGNMENT.
To enable a CATTRON-THEIMEG
PSEZ & PSCS controller and receiver/decoder to communicate,
they must use the same RF frequency and digital address. PSEZ PRC system controllers and
receiver/decoders are capable of operating on up to 79 different frequencies and 126 addresses. PSCS
PRC system controllers and receiver/decoders are capable of operating on up to 127 different
frequencies and 65,000 addresses for maximum versatility.