User's Manual

Section 5, Page 4 01/2001, CATTRON
- THEIMEG
TM
PSEZ & CS Controllers - address/frequency verification, continued.
EXAMPLE #2: Sample CS System Label - Factory Settings:
Frequency 448.9000MHz
Address: 3 B F E
/ | | \
Digit #1 | | Digit #4
(‘High’ digit) | | (‘Low’ digit)
/ \
Digit #2 Digit #3
To determine a PS controller’s current settings, skip ahead to the paragraph on page 13 of this section
titled ‘Address, Frequency Bank, and Frequency report only’ for detailed instructions.
Programming PSEZ &CS Controller address and frequency.
WARNING:
FAILURE TO PROPERLY SELECT FREQUENCY AND ADDRESS MAY
RESULT IN THE UNINTENTIONAL OPERATION OF OTHER
MACHINERY AND COULD RESULT IN DEATH OR SERIOUS INJURY
TO PERSONNEL. DO NOT DUPLICATE ADDRESS ASSIGNMENT.
NOTES: (1) The ‘i-Key’ must match the two letter designation of the model
number, i.e. EZ, or CS. This is found on a label located on the
underside of the controller, and also on a label located inside the
battery compartment.
(2) The controller will not operate your target control system without
the correct address and operating frequency programmed.
Referring to Figure 5-1 below and the keypad function menu on the next page, the top four large
pushbuttons of the PSEZ and PSCS controller are used during the data entry mode.
As required, proceed to verify/program PS Controller address and frequency using the following
procedures: