User's Manual

Section 5, Page 6 01/2001, CATTRON
- THEIMEG
TM
Address digit #1 entry and report (CS controller only).
NOTE: The following Address Digit #1 and # 2 entry and reporting procedures are
not applicable to PSEZ Controllers. When programming a PSEZ Controller,
go directly to Address digit #3 entry and report and Address digit #4 entry
and report on pages 9 and 10 of this section.
Figure 5-1. PSEZ & CS Remote Controllers, keypad-programming layout
1. Referring to Figure 5-1 above, set the ON/OFF switch on the PSCS controller to ‘OFF’.
Make sure the red STOP Switch on the controller is unlatched and set to the ‘RUN’ (pulled
up) position.
NOTE: Provided a Frequency and Address has been programmed in the controller,
applying power to the controller with the red STOP Switch set to ‘STOP’
(pushed down) will immediately place the Controller in a STOP message
transmit cycle. If a Frequency and Address has not been pre-programmed in the
controller, the STOP message transmit cycle cannot be sent. Instead, the
controller will emit three long beeps and reset.
R
e
d
S
T
O
P
S
w
i
t
c
h
S
T
O
P
O
N
/
O
F
F
S
w
i
t
c
h
C
o
l
o
r
C
o
d
e
d
i
-
K
e
y
BUTTON #1
BUTTON #2
BUTTON #4
BUTTON #3
Button #1 and #2
are not used for
address digit select
or reports on
EZ
Z
controllers
NOTE: