Temperatures should not exceed the minimums or maximums presented in Table 20.
Table 20: Recommended maximum and minimum temperatures
Specification
Value
Unit
Temperature Inc./Dec. Rate (max)
1~3 °C / Sec
Temperature Decrease rate (goal)
2-4 °C / Sec
Soak Temp Increase rate (goal)
.5 - 1 °C / Sec
Flux Soak Period (Min)
70 Sec
Flux Soak Period (Max)
120 Sec
Flux Soak Temp (Min)
150 °C
Flux Soak Temp (max)
190 °C
Time Above Liquidous (max)
70 Sec
Time Above Liquidous (min)
50 Sec
Time In Target Reflow Range (goal)
30 Sec
Time At Absolute Peak (max)
5 Sec
Liquidous Temperature (SAC305)
218 °C
Lower Target Reflow Temperature
240 °C
Upper Target Reflow Temperature
250 °C
Absolute Peak Temperature
260 °C
13 J
APAN
(MIC)
R
EGULATORY
The BT800 is approved for use in the Japanese market. The part numbers listed below hold WW type
certification. Refer to ARIB-STD-T66 for further guidance on OEM’s responsibilities.
Model Product Name Description Certificate Number
BT860-SA
BT860-ST
BT v4.2 Dual Mode UART HCI
Module
Mounted with chipset antenna 201-170971
13.1. Antenna Information
The BT800 was tested with antennas listed below. The OEM can choose a different manufacturers antenna but
must make sure it is of same type and that the gain is lesser than or equal to the antenna that is approved for
use.
Item
Part Number Mfg. Type Gain (dBi)
1 AT3216-B2R7HAA
ACX Ceramic 0.5
2 001-0030 mFlexPIFA LAIRD PIFA 2
3 001-0014 FlexPIFA LAIRD PIFA 2
4 0600-00040 LAIRD Dipole 2
5 NanoBlue MAF94045 LAIRD PCB Dipole 2