User Manual

Page 13 of 39
Save Config to NV Memory (command button)
Permanently saves configuration settings from ID and RF Settings
pages to non volatile memory. This feature allows user to cycle
power or reset the module without losing previous saved settings.
4.2.2 Setting Device Identification (See Figure 4-1)
Transceiver Address
Short Address – Device defaults to using short address unless
this field is set to 65,534. If using short address protocol only
use values from 0 to 65,533
Long Address – Eight byte address used for communication
between devices if short address is set to 65,534.
Set Transceiver Address – Sets Long and Short Address*
Get Transceiver Address – Gets Long and Short Address*
PAN ID (Personal Area Network Identification)
Set PAN ID – Range 0 to 16383 (14 bit Value)
Get PAN ID – Returns current PAN ID
4.2.3 RF Settings (See Figure 4-3)
The RF Settings page can be accessed by selecting the RF settings tab in
the software and is shown in Figure 4-3. The following features are provided
in the RF settings page.
Acknowledgement Settings* – If enabled the destination
device will transmit an acknowledgement to the originating
device. If disabled the destination device will not send an
acknowledgement back to the originating device. Query
Acknowledgement settings displays current setting in text box.
Receive All Messages Setting* - If enabled all messages will
be received from devices with same PAN ID and RF Channel
and will inhibit device from transmitting. This feature is only to
be used for diagnostic purposes.
Set or Query RF Channel* - channels 11 – 26 may be used
Set or Query Transmitter Power Level* - Ranges from 0 – 31
(31 is max level)
Set RF Module Power Mode for Sleep, Idle, or Wakeup.
* To permanently save select the “Save Config to NV Memory”