Datasheet
48
www.lairdtech.com
49
www.lairdtech.com
EMI ESSENTIALSEMI ESSENTIALS
VENT PANELS
Laird has various vent panels to t specic application needs.
Laird shielding ventilation panels are available in a wide array of materials, platings and mounting congurations.
Vent panels offer designers new versatility to meet EMI, environmental and mechanical system requirements.
When custom designs are needed, Laird engineering staff helps construct efciencies in performance, cost and manufacturability
from the very beginning stages of the application.
PANELS
For additional information on any of the other products available, please contact sales for assistance or visit us at www.lairdtech.com.
36
COMBINING EMI INNOVATION
AND COST EFFICIENCY
Air Flow Volume Difference
MaxAir vs. Al Vent Panel w/0.25" Wide Frame
0%
10%
20%
30%
40%
50%
0.05 0.10 0.15 0.20 0.25 0.30 0.35
Pressure Drop (inches H
2
O)
6" x 6" Vent Panel
18" x 18" Vent Panel
Shielding Effectiveness per MIL-STD-285 (mod.)
Frameless Vent Panel w/Conductive Foam Band,
(0.5" Thick, 0.125" Cell )
Frequency (MHz)
200
300
400
500
600
700
800
900
2000
3000
4000
5000
6000
7000
8000
9000
1000
10000
0
10
20
30
40
50
60
70
80
90
100
110
MaxAir Vent Panel
Framed Al Vent Panel
Air Flow Volume Difference
MaxAir
TM
vs. Aluminum Vent Panel w/ 0.250” Wide Frame
VP
Shielding Effectiveness per MIL-STD-285 (mod.)
Frameless ent anel w/compressible conductive perimeter gasket
(0.500”Thick, 0.125”Cell)
MaxAir
TM
Vent Panel
Framed Aluminum Vent Panel
Laird's patented MaxAir vent panel product line provides
an innovative cost effective approach for providing
increased airflow and EMI protection for
telecommunications hardware equipment such
as fans and server racks.
This metallized polycarbonate honeycomb material
provides a rigid medium eliminating the need for costly
frame designs. This frameless design allows greater airflow
through the entire honeycomb surface and ease of
installation through its press-to-fit assembly. The MaxAir
vent panel provides greater durability and flexibility than
traditional aluminum vent panels.
Varying densities of material are available to meet specific
levels of rigidity requirements. The honeycomb cell size can
be 0.125 in (3,18mm) or 0.250 in (6,35mm) in standard
thicknesses of 0.250 in (6,35mm) and 0.500 in (12,70mm).
MaxAir
TM
• Metallized polymeric honeycomb provides excellent product
rigidity and dent resistance
• Eliminates frames, rivets and costly labor to install
• UL 94 V0 rated or intumescent coated versions available
for flame resistance
• Increases useable air flow area by 10% to 20% compared to
framed aluminum vent panels
• Special features can be machined into honeycomb, such as
recesses and rabbet cuts to customize panel
• Half the weight of traditional aluminum honeycomb
vent panels
• Compressible conductive perimeter gasket provides extensive
tolerance to accommodate variations in shelf widths or vent panel
opening dimensions
• Can be manually inserted with slide-in motion or by
compression fit utilizing compression stops and minimal
hardware
APPLICATIONS:
• Telecommunications hardware equipment
• Fans • Military applications
• Server racks • Shielded rooms
Features and Benefits:
VENT PANELS
MAXAIR
™