FLOW ALARMS www.lakemonitors.
NOTE: Installation, operation and cleaning instructions for the basic flow meter cartridge can be found in the first section of this manual. The following instructions are specifically for meters with electrical switches for flow alarms. General Information Lake’s Flow Alarms are typically used to make or break a set of electrical contacts to signal a limit setting. They may be used to turn on a warning light, sound a bell or horn, or even to shut down a process.
The pointer indicates the set point for the alarm switch. In Illustration 1, the switch will be actuated at all flow rates below 4 GPM. To change the set point, simply loosen the switch glide screw one (1) turn and slide the switch to the desired position along the flow rate scale. When the pointer is pointing to the desired flow rate, re-tighten the switch glide screw.
Switches Specifications Type Form C, dry contact UL/CSA Rating 10 & 1/4 hp, 125 or 250 VAC 1/2 A, 125 VDC & 1/4A, 250 VDC 3A, 125 VAC “L” lamp load Mechanical Life >10,000,000 cycles Actuating Mechanical Simulated roller, lever operated, low force Connectors 3/16" tab Double Break Switch (Special) Form Z - 10A &1/2hp, 125/250 VAC Electrical Connections Standard Flow Alarms are pre-wired with 4pin Hirschmann-type DIN connectors which consist of a male section as shown in Illustration 4 and the Il
Illustration 7 shows the connections for a standard, single switch Flow Alarm as they are shipped from the factory. The wiring for other types of connections are outlined in the tables below. For additional details, please consult the factory or your authorized Lake distributor. Alternates to the standard Hirschmann-type DIN connector are available on a custom basis.
Standard Control Circuits Page 6 / Flow Alarms / Lake Manual
* The load must be within the flow alarm’s and the slave relay’s contact rating. Please see specifications.
NOTES: _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _
NOTES: _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _