Instruction Manual

Installation In
7 Easy Steps
1. Remove the TWISTIICLEAN
from its box.
2. Be sure the clear bowl is securely
tightened (hand tighten only).
The unit is shipped with the
bowl loose. Remove the safety
bolt and wing-nut that keeps the
handle from turning. Rotate the
top handle a few times to make
sure it will rotate ¼ clockwise
turn.
3. Prepare the piping manifold to
install TWIST
IICLEAN. Notice
the direction of water ow through
the unit -- a ow direction arrow
is molded into the side of the
unit. (Fig A).
4. If PVC mating flanges are installed use proper PVC
solvents and follow gluing instructions on solvent
container. Do not spill solvent on any part of the
TWIST
IICLEAN unit.
5. Ensure that suitable pipe supports are used. Do not use
the lter as a pipe support.
6. Once installed, test by turning water supply on slowly,
allowing water to feed through the unit. Check for
leaks. After removing the safety bolt and wing-nut,
twist the top handle with a ¼ clockwise turn to re-direct the
ow for cleaning. This should lift the screen element inside
the bowl and release ush water through the purge exit at
the bottom of the unit. Twist the handle back to its “run”
position, replace safety bolt and wing-nut and check for
leaks.
7. Attach a ush drain hose (recommended) to direct the
purged particle matter and excess water to a drain or other
desired area for discharge (Fig B).
A. Select a good lter location:
Install on the pressure (outlet) side of any pumps and
pressure tanks (if applicable)
In a vertical position with purge exit pointing down
Away from extreme weather conditions to protect
from freezing
At least 12 inches away from walls or obstructions,
so top handle can be twisted
Allow enough clearance beneath the unit to:
(a) attach a purge drain hose to the purge exit
(recommended)
(b) remove the clear bowl assembly, to allow
replacement of element as needed
B. As a sunny outdoor installation might lead to algae
growth inside the clear bowl and affect the operation
of your TWIST
IICLEAN, an optional Sun Shield is
available.
Maximum Flow Range:
• T2C-200HF2"Flang ed
Inlet/Outlet:0to150USgpm(0to34m³/hr)
Maximum Pressure:
• 100psiat73˚F(6.9barat38˚C)
Temperature Range:
• 32˚F-120˚F(0˚C-49˚C)
Mesh Sizes:
• 60Mesh(250Micron)Element
• 100Mesh(150Micron)Element
• 140Mesh(105Micron)Element
• 200Mesh(74Micron)Element
Pre-Installation Checklist
SafetyBolt
&Wing-nut
Inlet
Outlet
FlowDirectionArrow
4BoltFlanged
Mount
ClearBowl
FilterElement
PurgeExit
LS-896 (11/12)
Inlet/Outlet to Purge Port
Total Length
TWISTIICLEAN High Flow
Installation Instructions for: 2-inch Model T2C-200
Installation and
Operation Guide
Width
Fig A
Fig B
Optional Accessories
Sun Shield For Outdoor
Installations
Black neoprene woven cover, slips
over bowl to prevent growth of algae
and other organics.
Purge
Exit
Hose
Model Size Sun Shield Part Number
T2C-200(2")
131354
SUN SHIELD
Total
T2C-200
4BoltFlanged
3/4”MPT
24.92”
10.22”
18.28”
Top
Handle

Summary of content (2 pages)