Instructions / Assembly

Dry-Coat™ DC-3045 / 3047 / 3048
Surface Preparation:
All surfaces must be dry, clean, sound and free of contaminants such as
dirt, grease, chalk, mildew, oil, rust, concrete curing agents, chalk, laitance,
efflorescence, mildew, loose or badly cracked paint. Remove all
contaminants by washing surfaces with an appropriate cleaner, sanding,
scrapping and/or using a pressure washing machine.
Prime if required as per recommended specifications of this product for
surfaces like: concrete, plasters, gypsum wallboard, drywall, wood,
plywood, steel, aluminum, galvanized steel, other composition materials or
vinyl siding with the recommended Lanco
®
primer or primer/sealer,
following application instructions. Glossy surfaces should be lightly sanded
and primed previous to new paint application.
Cracks and holes have to be clean and dry, with a putty knife apply Crack
Filler, into crack and 2 inches to both sides, patch all holes with Lanco
®
Spackling Compound and let dry thoroughly 24 hours.
Recommended Specications:
Mildewed Surfaces: This paint contains agents to inhibit the mildew
growth on the dried paint film itself. Any existing mildew on the surface
must be completely killed and removed prior to the application of primer or
paint. Any mildew not removed may continue to grow through the new
finish. Using a long-handled brush, scrub mildewed surfaces with a mixture
of one part of household bleach and three parts of warm water. Rinse
completely and let dry.
Concrete Surfaces: Mortar plaster, stucco and concrete block must be
cured and hard. Remove any surface contaminant, form release and curing
agents or efflorescence, surface must have a safe pH level under 9 prior to
the application of paint or primer.
Eforescence: Is a white powdery, crystal-like deposit that is visible on
masonry surfaces. It must be removed using a 1:3 solution of 1 part of
muriatic acid and 3 parts of water. Use long handled brush. Rinse
completely.
CAUTION: Read cleaning solution warnings on label prior to use.
Repair Cracks:
Above grade or architectural walls - Make sure cracks and holes are clean &
dry. With a putty knife apply a crack filler into crack and 2 inches to both
sides. Let dry thoroughly 24 hours before applying Lanco
®
Dry-Coat™.
Below grade or retaining walls - Make sure cracks & holes are clean, dry &
free of loose particles. Patch all holes & cracks using a good quality, fast
setting hydraulic cement, and smooth the patch evenly with the surface
around it. Floor joints where walls & foors meet must be checked, for
possible breaks. If necessary fll with a good quality fast setting hydraulic
cement.
Previously Painted Surfaces: All surface contaminants such as oil, grease,
mill scale, dirt, mold, mildew mortar, efflorescence and sealer must be
removed to assure sound bonding to the previous finish. Old coatings that
are partially removed or loose by blistering, rupture or scratching should be
removed to provide a sound surface. Sand any glossy areas and dust clean,
wipe away dirt, chalk. Prime properly prepared concrete, wood, plywood,
composition materials and vinyl siding with a primer. Use a 100% Acrylic
primer on chalky surfaces following label instructions. Glossy surfaces
should be lightly sanded and primed previous to new paint application.
Application:
Stir thoroughly before using. Paint always on shaded side of the building.
Do not dilute paint, use as supplied. Do not apply when surface or air
temperature is below 50 ˚F or if rain is expected within 5 hours. Apply
product with brush, roller or sprayer. Apply generously with a full brush or
roller and avoid excessive brushing or spreading too thinly. Typical
standard practice recommends intermixing when working with more than
one container of the same color, to ensure color consistency.
Mixing and Thinning: Mix always thoroughly before application. Thinning
is not recommended, if necessary use only 8oz. of water per gallon of this
product.
Brush: Use a good quality nylon or polyester brush.
Roller: Use a All-Purpose 3/8” Roller. Apply generously, but avoid
excessive brushing or reworking of painted areas, do not apply or
spreading too thinly.
Spray: Spray: Spray equipment should be capable of maintaining a
pressure of 1,500-2,000 psi with a tip of .019 to .021.
Spray and back roll on rough or porous surface to achieve required film
build. Apply two coats with overnight drying between coats to minimize
pinholes on the surface is recommended. See equipment’s manufacturer
recommendation.
Precaution: Do not apply when air or surface temperature is below 50 ˚F
(10 ˚C). Apply liberally,but do not overspread. Stop painting at least two
hours before you expect dew to form or the temperature to fall below 50 ˚F
(10 ˚C).
IMPORTANT: It is important that you apply one coat of primer and two full
coats of paint to achieve the warranty protection.
CAUTION: Harmful if swallowed. Contains Acrylic Resin. In case of eye
contact, flush thoroughly with water. Do not rub eyes. In case of skin
contact, flush area immediately with clean water. If swallowed, do not
induce vomiting. CONSULT A PHYSICIAN IMMEDIATELY. USE ONLY
WITH ADEQUATE VENTILATION. Adequate ventilation required when
sanding or abrading the dried film. Always use (NIOSH/MSHA TC21C or
equivalent.) Goggles are recommended while handling the product. This
product may contain chemicals known to the State of California to cause
cancer and birth defects or other reproductive harm. KEEP OUT OF REACH
OF CHILDREN.
WARNING! If you scrape, sand, or remove old paint, you may release lead
dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS
ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN.
PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a
NIOSH-approved respirator to control lead exposure. Clean up carefully
with a HEPA vacuum and a wet mop. Before you start, find out how to
protect yourself and your family by contacting the National Lead
Information Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead. For
chemical emergency call ChemTrec 1-800-424-9300. PROTECT FROM
FREEZING.

Summary of content (1 pages)