TDS

Waterproong & Crack Isolation Base Membrane
Aqua-Proof
MD-863
Description:
Aqua-Proof™
is a liquid membrane of styrene
/butadiene latex that provides an easy
alternative for many roofing and waterproofing
applications as a base membrane. This
monolithic membrane provides excellent
performance when used as a base coat over
horizontal or vertical surfaces, and performs
extremely well during continuous water
immersion test. May be used under render and
plaster, or between concrete slabs as a weather
or vapor barrier.
Product Advantages:
• Can be applied to damp substrates
• Excellent adhesion to asphalt surfaces
• Water based, non-toxic, free of solvents
• Quick drying, touch-dry in one hour
• Highly flexible rubber coating
• Excellent crack-bridging properties
• Low V.O.C., volatile organic compound and
non-flammable
• High alkalinity resistance
• Applies blue and dries in black color
Uses:
Aqua-Proof™ has proven excellent as a main
waterproof coating or as part of a roofing
system over a variety of substrates like
modified asphalt membranes, built-up roofs,
polyurethane foam, concrete surfaces, bonded
tar, granulated shingles EPDM and TPO. Can
be used as a waterproofing system in planters
or below grade applications. Always have to be
protected from UV radiation. May be used as a
protection under tiles in wet areas such as
bathrooms, food processing areas, balconies.
Notice: The technical data contained herein are
true and accurate to the best of our knowledge.
Published technical data and instructions are
subject to change without prior notice.
S.D.S.: Available upon request.
Surface Preparation:
Surface must be clean, sound, and free of dust
or loose material. Remove all debris and old
loose coatings by means of high-pressure
water blasting or wire brushing. Any existing
mildew on the surface must be completely
killed and removed prior to the application of
this product. Scrub mildewed surface with a
mixture of 1 quart of household bleach with 3
quarts of warm water. Rinse completely and let
dry.
Roong System Recommendations:
When used as a stand-alone product in the
roofing system apply AquaProof™ at a rate of
80 ft.
2
/gal.
When used in combination with Polyester
Fabric Mesh FM-222 apply Aqua-Proof to
embed the polyester fabric at a rate of 40ft.
2
/gal.
In roofs with polyester mesh:
1
st
coat + mesh: Aqua-Proof™ 40 ft.
2
./gal.
Install mesh and press down to saturate.
2
nd
coat: Urethanizer™ 40 p
2
/gal.
In roofs without polyester mesh:
1
st
coat + mesh: Aqua-Proof™ 80 ft.
2
/gal.
2
nd
coat: Urethanizer™ 50 ft.
2
/gal.
3
rd
coat: Urethanizer™ 50 ft.
2
/gal.
Floor System Recommendations:
In floor waterproofing system with mesh,
apply a first coat of AquaProof™ at a rate of
50ft.
2
/gal. in systems without mesh apply at a
rate of 80 ft.
2
/gal.
In interior oors without polyester mesh:
1
st
coat: Aqua-Proof™ 80 ft.
2
/gal.
2
nd
coat: Aqua-Proof™ 100 ft.
2
/gal.
3
rd
coat: Aqua-Proof™ 100 ft.
2
/gal.
In exterior oors with polyester mesh:
1
st
coat: Aqua-Proof™ 50 ft.
2
./gal.
2
nd
coat + mesh: Aqua-Proof™ 40 ft.
2
/gal.
Install mesh and press down to saturate.
3
rd
coat: Aqua-Proof™ 100 ft.
2
/gal.
ASTM D 6083: Yes
Energy Star: N/A
Miami-Dade County: N/A
VOC Compliant (<100 g/L): Yes
SCAQMD: Passes
AIM & OTC: Passes
Meets Requirements for:
TECHNICAL DATA SHEET
Product Type: Styrene Butadiene
Solids (%): 58 ± 2% by weight
54 ± 2% by volume
Weight/Gallon: 9.18 ± 0.05lbs.
(4.22 ± 0.02kg.)
Color: Applies blue and dries
Black
Drying Time:
ASTM D1640 To touch: 30-60 min
To recoat: 2-4 hrs
Coverage:
On Concrete: 80 ft.
2
/gal.
(7.4 m
2
/gal.) @
11 dry mils, 20 wet mils
Can Sizes: 5 gallons
1 gallon
Thinning: Is not recommended
Flash Point: Non-flammable
Viscosity: 90 - 100 KU's
Percent Pigment
by Weight: 15 ± 2%
VOC: 4 g/L
Technical Data:
Method of Application:
Apply with a Lanco
®
3/4" Nap Rough Surface Roller PA-568 or airless spray.
Wait 24 hours between coats. Apply only when temperature is above 50˚F
(10˚C). Do not apply if temperature is expected to drop below 50˚F (10˚C)
before the coating has completely dried. Two full coats are generally needed
for proper sealing. Always apply coats in different directions. Never thin or
dilute from full strength.
Recommended equipment: Use an airless pump with pressure of 1,500 to
2,000 psi. A fluid delivery of 1 to 2 gallons per minute with a spray tip of
0.026 to 0.035 will be adequate. Wait 24 hours between coats. The hoses
should be at least 3/8" inside diameter and of the high-pressure rate type. If
the hose length is more than fifty feet, a larger inside diameter will be
required.
Cleanup: Clean roller and equipment after use with warm soapy water.
Drying time: Approximately 60 minutes to touch. Cure time is controlled by
thickness of the applied coating, relative humidity and temperature. Allow 24
hours between coats.
Limited warranty: The manufacturers liability in connection with the sale of
this product extends only to the replacement price if it should fail to comply
with quality standards or specifications. Protect from freezing.
Warning!: Do not allow product to freeze. Do not store in temperatures
above 105°F. Protective clothing and eyewear should be used during
application of this product. Ensure that lid is tight and pail is upright and
secure before transporting. Do not allow pail to roll as this may cause lid to
loosen and allow leakage to occur. Transport product placed on top of a
protective cloth in cargo area of vehicle to prevent damage from accidental
spills.
Cautions: Contains styrene butadiene and acrylic resin. In case of eye
contact, flush thoroughly with water. Do not rub eyes. In case of skin
contact, flush area immediately with clean water. If swallowed, do not
induce vomiting. Consult a physician immediately. Use only with adequate
ventilation. Keep out of reach of children.
www.lancopaints.com continued on back
Performance:
Tensile Strength N/A
ASTM D 2370
Elongation N/A
ASTM D 2370
Wet Adhesion to concrete N/A
ASTM ASTM C 794 / D 903
Water Permeability N/A
ASTM D 1653
Solar Reflectance N/A
ASTM C 1549