Streetlight Arm Installation Procedure
.
Figure 4 - 14. Pole mounted concentrator assembly illustration
Install the concentrator approximately 18" below the lowest portion on the light head arm.
1. Thread the four rods through the two included metal brackets.
2. Hold the concentrator on the front of the pole while threading the rods through the enclosure
from the back of the pole.
3. Place nuts and washers on the four threaded rods and tighten until secure.
4. Assemble the antennas, ground planes, and RF cables. Leave slack in the cables to form a drip
loop.
5. To connect the adapter, remove the photocell on the existing light head.
6. Install the adapter.
7. Lock it into place by turning clockwise.